Quantitative evaluation of radiation-induced lung injury with hyperpolarized xenon magnetic resonance.
نویسندگان
چکیده
PURPOSE To demonstrate the feasibility of quantitative and comprehensive global evaluation of pulmonary function and microstructural changes in rats with radiation-induced lung injury (RILI) using hyperpolarized xenon MR. METHODS Dissolved xenon spectra were dynamically acquired using a modified chemical shift saturation recovery pulse sequence in five rats with RILI (bilaterally exposed by 6-MV x-ray with a dose of 14 Gy 3 mo. prior to MR experiments) and five healthy rats. The dissolved xenon signals were quantitatively analyzed, and the pulmonary physiological parameters were extracted with the model of xenon exchange. RESULTS The obtained pulmonary physiological parameters and the ratio of (129) Xe signal in red blood cells (RBCs) versus barrier showed a significant difference between the groups. In RILI rats versus controls, the exchange time increased from 44.5 to 112 ms, the pulmonary capillary transit time increased from 0.51 to 1.48 s, and the ratio of (129) Xe spectroscopic signal in RBCs versus barrier increased from 0.294 to 0.484. CONCLUSION Hyperpolarized xenon MR is effective for quantitative and comprehensive global evaluation of pulmonary function and structural changes without the use of radiation. This may open the door for its use in the diagnosis of lung diseases that are related to gas exchange. Magn Reson Med 76:408-416, 2016. © 2015 Wiley Periodicals, Inc.
منابع مشابه
Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications.
During the past several years there has been extensive development and application of hyperpolarized helium-3 (HP (3)He) magnetic resonance imaging (MRI) in clinical respiratory indications such as asthma, chronic obstructive pulmonary disease, cystic fibrosis, radiation-induced lung injury, and transplantation. This review focuses on the state-of-the-art of HP (3)He MRI and its application to ...
متن کاملProton and hyperpolarized helium magnetic resonance imaging of radiation-induced lung injury in rats.
PURPOSE To assess the usefulness of hyperpolarized helium (3He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. METHODS AND MATERIALS Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 x 8 Gy) using 4-MV photons. Conventional proton (1H) and hyperpolarized (3He) MRI wer...
متن کاملIology Contribution Proton and Hyperpolarized Helium Magnetic Resonance Imaging of Radiation-induced Lung Injury in Rats
Purpose: To assess the usefulness of hyperpolarized helium (He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. Methods and Materials: Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 8 Gy) using 4-MV photons. Conventional proton (H) and hyperpolarized (He) MRI were use...
متن کاملComparison of Hyperpolarized He and Xe for Measurement of Absolute Ventilated Lung Volume of Rat Lungs
Introduction: Magnetic Resonance (MR) imaging using hyperpolarized noble gases (HNG), He and Xe, provides a non-invasive approach for probing both lung function and structure. In particular, measurement of HNG ventilated lung volumes (e.g. ventilation defects) are useful for characterizing chronic obstructive pulmonary disease (COPD)[1], quantifying xenon diffusing capacity in inflammatory dise...
متن کامل3D Hyperpolarized (129)Xe MRI of mouse lung at low xenon concentration using a continuous flow-type hyperpolarizing system: feasibility for quantitative measurement of regional ventilation.
PURPOSE We investigated the feasibility of 3D hyperpolarized (HP) (129)Xe magnetic resonance (MR) imaging at an extremely low concentration of HP (129)Xe supplied from a continuous flow-type hyperpolarizing (CF-HP) system and established a standard procedure for measuring regional lung ventilation of small animals, such as the mouse, as a baseline for further studies. MATERIALS AND METHODS We...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 76 2 شماره
صفحات -
تاریخ انتشار 2016