Microtensile bond strength of resin-based composites to Ti-6Al-4V.

نویسندگان

  • Carlos A Fernandes
  • José C Ribeiro
  • Brian S Larson
  • Estevam A Bonfante
  • Nelson R Silva
  • Marcelo Suzuki
  • Van P Thompson
  • Paulo G Coelho
چکیده

OBJECTIVE The purpose of this study was to determine the microtensile bond strength of various resin composite/adhesive systems to alumina particle abraded Ti-6Al-4V substrate after aging for 24h, 10 days, and 30 days in distilled water at 37 degrees C. METHODS Four laboratory resin composite veneering systems (Gradia, GR; Solidex, SOL; Ceramage, CER; and Sinfony, SF) were bonded to 25 mm diameter machined disks of Ti-6Al-4V with their respective adhesive and methodology, according to the manufacturer's instructions. Microtensile bars of approximate dimensions 1 mm x 1 mm x 6 mm were prepared for each resin composite/adhesive system. After cutting, groups (n=12) from each adhesive system were separated and either stored in water at 37 degrees C for 24h (baseline) or aged for 10 or 30 days prior to loading to failure under tension at a cross head speed of 1.0mm/min. Failure modes were determined by means of scanning electron microscopy (SEM). Statistical analysis was performed through one-way ANOVA and Tukey's test at 95% level of significance. RESULTS Significant variation in microtensile bond strength was observed for the different systems and aging times. SOL and GR showed the highest mean bond strength values followed by SF and CER at baseline. Aging specimens in water had an adverse effect on bond strength for SOL and CER but not for the SF and GR groups. SIGNIFICANCE In vitro bond strength of laboratory resin composites to Ti-6Al-4V suggests that strong bonds can be achieved and are stable for certain systems, making them useful as an alternative for esthetic fixed prosthetic restorations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of microtensile bond strength of repaired dental resin composite using different surface treatment techniques: A laboratory study

Background and Aims: Today, resin composites are one of the most commonly used materials in restorative dentistry. However, failure in resin treatments is also common due to its chemical nature and its high talent for decay recurrence. According to conservative approaches, "conservative" treatments are more likely to be considered than "Replacement" of damaged remedies. The purpose of this stud...

متن کامل

Shear bond strength of composite resin to titanium according to various surface treatments

STATEMENT OF PROBLEM When veneering composite resin-metal restoration is prepared, the fact that bond strength between Ti and composite resin is relatively weak should be considered. PURPOSE The purpose of this study is to evaluate the shear bond strength between the veneering composite resin and commercial pure (CP) Ti / Ti-6Al-4V alloy according to the method of surface treatment. MATERIA...

متن کامل

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

STATEMENT OF PROBLEM The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND METHODS Disks of commercially...

متن کامل

The Thermal Stability of Anodic Oxide Coatings – Strength and Durability of Adhesively Bonded Ti-6Al-4V Alloy by

The lap shear strength of chromic acid anodized, primed, Ti-6Al-4V alloy bonded with a high performance FM-5 polyimide adhesive has been investigated as a function of thermal treatment for selected times at various temperatures in air. The research findings indicate that the lap shear strength decreases with the increase in duration of the thermal treatment at constant temperature and with the ...

متن کامل

Evaluating Resin-Dentin Bond by Microtensile Bond Strength Test: Effects of Various Resin Composites and Placement Techniques

OBJECTIVES This in vitro study evaluated the microtensile bond strength (MTBS) of a methacrylate-based compared to a silorane-based resin composite in Class I cavity using different placement techniques. MATERIALS AND METHODS Class I cavities with dimension of (4 mm long, 4 mm wide, 3 mm deep) were prepared in extracted sound human molars. The teeth were randomly divided into six groups. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 25 5  شماره 

صفحات  -