Effect of hydrodynamic parameters on corneal endothelial cell loss after phacoemulsification.

نویسندگان

  • Alireza Baradaran-Rafii
  • Mohsen Rahmati-Kamel
  • Medi Eslani
  • Victoria Kiavash
  • Farid Karimian
چکیده

PURPOSE To evaluate the effect of power, vacuum, and flow rate on endothelial cell loss after phacoemulsification. SETTING Labbafinejad Medical Center Medical Center, Tehran, Iran. METHODS In a prospective randomized clinical trial, phacoemulsification was performed in 2 groups (high vacuum and low vacuum) with 3+ nuclear sclerosis. The stop-and-chop technique was used with the Sovereign machine. Machine parameters during the chop stage were vacuum 400 mm Hg in the high-vacuum group and 200 mm Hg in the low-vacuum group and flow rate, 40 cc/min and 20 cc/min, respectively. Endothelial cell density preoperatively before and 1, 6, and 12 weeks postoperatively were compared. RESULTS Each group comprised 30 eyes. The mean US power was 9.2% +/- 4.3% (SD) in the low-vacuum group and 13.1% +/- 4.6% in the high-vacuum group (P = .001) and the mean phaco time, 1.28 +/- 1.0 minutes and 0.88 +/- 0.6 minutes, respectively (P = .04). Total US energy and total fluid consumed were similar between groups. After 12 weeks, the mean endothelial cell loss was 9.0% +/- 4.0% in the low-vacuum group and 9.6% +/- 4.6% in the high-vacuum group (P = .6). There was a relationship between total US energy and endothelial loss (P<.001); however, total fluid volume was not a significant predictor (P = .19). CONCLUSIONS Vacuum level did not have a significant effect on total US energy or total fluid consumed during phacoemulsification. There was a strong relationship between total US energy and endothelial cell loss but not between total infused fluid and endothelial cell loss.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modern techniques can significantly reduce endothelial cell loss after cataract surgery

TORSIONAL phaco and the soft-shell technique are among the means available to surgeons for reducing endothelial cell loss to a minimum after cataract procedures, said Rudy Nuijts MD, University Hospital, Maastricht,The Netherlands. At every stage of a cataract procedure the surgeon has options that can optimise corneal endothelial safety.The relevant parameters include the machines, materials, ...

متن کامل

Risk Factors for Endothelial Cell Loss after Phacoemulsification: Comparison in Different Anterior Chamber Depth Groups

PURPOSE To assess the risk factors for endothelial cell loss after phacoemulsification with implantation of intraocular lens according to anterior chamber depth (ACD). METHODS This prospective study included 94 eyes of 94 patients undergoing phacoemulsification cataract surgery. To assess the risk factors for corneal endothelial cell loss, we examined seven variables at 1 day, 1 week, 6 weeks...

متن کامل

Effect of bevel position on the corneal endothelium after phacoemulsification.

PURPOSE To compare the extent of corneal endothelial (CE) cell loss changes in two groups of eyes submitted to phacoemulsification, with the conventional bevel-up tip position in one eye and with the bevel-down tip position in the fellow eye. METHODS This prospective clinical trial comprised 25 patients with bilateral cataracts subjected to lens removal by phacoemulsification with the convent...

متن کامل

Bevel tip position and corneal damage during phacoemulsification.

Bevel tip position and corneal damage during phacoemulsification Recently, Faramarzi et al. reported on bevel-up versus bevel-down phaco tip during phacoemulsification. We disagree with the authors that it was the first study to consider this subject. Other authors have published studies considering the consequences of phaco needle bevel position on corneal endothelial cells during phacoemulsif...

متن کامل

Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

PURPOSE To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). SETTING Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. METHODS 52 patients with cataract were randomly assigned to longitudinal ultra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2009