MeV Gamma-Ray Imaging Detector with micro-TPC
نویسنده
چکیده
We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed event by event. Furthermore, one of two measured (zenith and azimuth) angles of a recoil electron gives us an additional redundancy which enables us to reject the background events by kinematic constraints. In order to measure the track of a recoil electron, the micro Time Projection Chamber(μ-TPC) has been developed, which can measure the successive positions of the track of charged particles in a few hundred micron meter pitch. The μ-TPC consists of the new type of a gas proportional chamber: micro PIxel gas Chamber (μ-PIC) which is one of wireless gas chambers and expected to be robust and stable. Using this μ-TPC and the Anger camera for the detection of a scattered gamma ray, we have obtained the first gamma-ray image by the full reconstruction of the direction of gamma rays event by event.
منابع مشابه
ar X iv : a st ro - p h / 04 12 04 7 v 1 2 D ec 2 00 4 Development of an advanced Compton camera with gaseous TPC and scintillator
A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We de...
متن کاملPerformance of the TPC with Micro Pixel Chamber Readout: micro-TPC
Micro-TPC, a time projection chamber (TPC) with micro pixel chamber (μ-PIC) readout was developed for the detection of the three-dimensional fine (∼ sub-millimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector, or the μ-PIC, with the detection area of 10 × 10 cm and 65536 anode electrodes of 400 μm pitch. We achieved the gas gain of more than 1...
متن کاملar X iv : a st ro - p h / 00 12 29 7 v 1 1 3 D ec 2 00 0 Spectroscopy and Imaging Performance of the Liquid Xenon Gamma - Ray Imaging Telescope ( LXeGRIT )
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic γ–rays in the energy band of 0.2-20 MeV. The detector, with 400 cm 2 area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual γ–ray inte...
متن کاملA Position Sensitive Detector for 1 - 10 MeV Gamma RaysJoel
A position sensitive detector for 9 MeV gamma rays has been developed as part of a contraband detection system for airports. The system images contraband, such as explosives or drugs, in a geometry similar to medical x-ray computed tomography. A point source of gamma rays shines through an unknown object. Transmission projections of the areal density of detected gamma rays are reconstructed int...
متن کاملPerformance of a micro-TPC for a time-resolved neutron PSD
We report on the performance of a micro-TPC with a micro pixel chamber(μPIC) readout for a time-resolved neutron position-sensitive detector(PSD). Threedimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004