Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA

نویسندگان

  • Valentim Adelino Ricardo Barão
  • Wirley Gonçalves Assunção
  • Lucas Fernando Tabata
  • Edson Antonio Capello de Sousa
  • Eduardo Passos Rocha
چکیده

The study aimed to evaluate the effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures using a two-dimensional finite element analysis. Models were used in order to simulate two situations. In group A, model represented an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system while in group B, model simulated an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system associated with two-distally placed o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) in the resiliencies: hard, resilient and soft, respectively. Evaluation was performed on Ansys software. Group A showed higher stress values regardless of the mucosa characteristics. Overall, stress decreased at the supporting tissues as mucosa thickness and resiliency increased. Regarding supporting tissues, cortical bone showed the highest stress values. The use of bar-clip attachment system with distally placed o'ring attachment design optimized the stress distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Effects of Mucosal Thickness on the Stress Distribution and Denture Stability of Mandibular Implant-Supported Overdentures with Unsplinted Attachments In Vitro

The aim of this study was to compare the effects of mucosal thickness on the stress pattern around implants and movement of implant-supported overdentures with ball/female and three different types of magnetic attachments. After insertion of two root-form implants into a mandibular model, the surface of the model was covered with a 1.5- or 3-mm layer of impression material to simulate the oral ...

متن کامل

Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: A finite element analysis study.

STATEMENT OF PROBLEM The use of soft liners as female receptacles for ball attachments retaining immediately loaded implant overdenture has been recommended to enhance osseointegration and provide a shock absorbing effect. However, which liner and which thickness is still unclear. PURPOSE The purpose of this finite element analysis (FEA) study was to evaluate the effect of a 2- and 4-mm thick...

متن کامل

Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 92 2  شماره 

صفحات  -

تاریخ انتشار 2008