Pii: S0042-6989(97)00438-0
نویسندگان
چکیده
Line drawings produced by contours traced on a surface can produce a vivid impression of the surface shape. The stability of this perception is notable considering that the information provided by the surface contours is quite ambiguous. We have studied the stability of line drawing perception from psychophysical and computational standpoints. For a given family of simple line drawings, human observers could perceive the drawings as depicting either an elliptic (egg-shaped) or hyperbolic (saddle-shaped) smooth surface patch. Rotation of the image along the line of sight and change in aspect ratio of the line drawing could bias the observer toward either interpretation. The results were modeled by a simple Bayesian observer that computes the probability to choose either interpretation given the information in the image and prior preferences. The model’s decision rule is noncommitting: for a given input image its responses are still probabilistic, reflecting variability in the modeled observers’ judgements. A good fit to the data was obtained when three observer assumptions were introduced: a preference for convex surfaces, a preference for surface contours aligned with the principal lines of curvature, and a preference for a surface orientation consistent with an object viewed from above. We discuss how these assumptions might reflect regularities of the visual world. © 1998 Elsevier Science Ltd. All rights reserved.
منابع مشابه
Observer biases in the 3D interpretation of line drawings
Line drawings produced by contours traced on a surface can produce a vivid impression of the surface shape. The stability of this perception is notable considering that the information provided by the surface contours is quite ambiguous. We have studied the stability of line drawing perception from psychophysical and computational standpoints. For a given family of simple line drawings, human o...
متن کاملDetecting saccades with jerk
In studies of smooth eye movements, saccades are often detected and removed from eye movement records during analysis. A simple and effective method for saccade detection is described; the method uses jerk (the third derivative of eye position with respect to time).
متن کاملMolecular genetic detection of female carriers of protan defects
Females heterozygous for congenital colour vision defects are of interest because they are believed to have cone photoreceptor ratios and cone photopigments that differ from normal. We describe a molecular genetic method to identify protan carriers that involves characterizing the genes that occur in the most upstream position in each of the X-chromosome photopigment gene arrays.
متن کاملEpisodic acute hypotonia after Nd:YAG laser capsulotomy—retinal function and choroidal swelling
In a patient with uveitis who had been treated with Nd:YAG laser capsulotomy after cataract surgery, several episodes of acute hypotonia occurred which were associated with changes in clinical tests of the eye and of visual function. Immunosuppressive and immunomodulating treatment appeared to reverse the changes in intraocular pressure and normalise the test results. The significance of these ...
متن کاملReversed-phi perception with motion-defined motion stimuli
Perception of reversed-phi with motion-defined motion (MDM) stimuli was examined while varying various parameters including eccentricity. For peripheral viewing, reversed-phi was observed at all displacements between 30 degrees and 135 degrees. The perception most prominent at 90 degrees, but was disrupted by dichoptic presentation. These results suggest operations of an energy-based motion sys...
متن کامل