Molecular diagnostics on microfabricated electrophoretic devices: from slab gel- to capillary- to microchip-based assays for T- and B-cell lymphoproliferative disorders.
نویسندگان
چکیده
BACKGROUND Current methods for molecular-based diagnosis of disease rely heavily on modern molecular biology techniques for interrogating the genome for aberrant DNA sequences. These techniques typically include amplification of the target DNA sequences followed by separation of the amplified fragments by slab gel electrophoresis. As a result of the labor-intensive, time-consuming nature of slab gel electrophoresis, alternative electrophoretic formats have been developed in the form of capillary electrophoresis and, more recently, multichannel microchip electrophoresis. METHODS Capillary electrophoresis was explored as an alternative to slab gel electrophoresis for the analysis of PCR-amplified products indicative of T- and B-cell malignancies as a means of defining the elements for silica microchip-based diagnosis. Capillary-based separations were replicated on electrophoretic microchips. RESULTS The microchip-based electrophoretic separation effectively resolved PCR-amplified fragments from the variable region of the T-cell receptor-gamma gene (150-250 bp range) and the immunoglobulin heavy chain gene (80-140 bp range), yielding diagnostically relevant information regarding the presence of clonal DNA populations. Although hydroxyethylcellulose provided adequate separation power, the need for a coated microchannel for effective resolution necessitated additional preparative steps. In addition, preliminary data are shown indicating that polyvinylpyrrolidone may provide an adequate matrix without the need for microchannel coating. CONCLUSIONS Separation of B- and T-cell gene rearrangement PCR products on microchips provides diagnostic information in dramatically reduced time (160 s vs 2.5 h) with no loss of diagnostic capacity when compared with current methodologies. As illustrated, this technology and methodology holds great potential for extrapolation to the abundance of similar molecular biology-based techniques.
منابع مشابه
Effects of hemoglobin C and S traits on eight glycohemoglobin methods.
Pure Appl Chem 1996;68:1831–6. 8. Colyer CL, Tang T, Chiem N, Harrison DJ. Clinical potential of microchip capillary electrophoresis systems. Electrophoresis 1997;18:1733–41. 9. Hofgärtner WT, Hühmer AFR, Landers JP, Kant JA. Rapid diagnosis of herpes simplex encephalitis using microchip electrophoresis of PCR products. Clin Chem 1999;45:2120–8. 10. Chen YH, Wang WC, Young KC, Chang TT, Chen SH...
متن کاملSingle-molecule DNA amplification and analysis in an integrated microfluidic device.
Stochastic PCR amplification of single DNA template molecules followed by capillary electrophoretic (CE) analysis of the products is demonstrated in an integrated microfluidic device. The microdevice consists of submicroliter PCR chambers etched into a glass substrate that are directly connected to a microfabricated CE system. Valves and hydrophobic vents provide controlled and sensorless loadi...
متن کاملFully integrated PCR-capillary electrophoresis microsystem for DNA analysis.
A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing ...
متن کاملCapillary electrophoresis is essential for microsatellite marker based detection and quantification of adulteration of Basmati rice (Oryza sativa).
Microsatellite markers are employed for genotyping of Basmati varieties and assaying purity of market samples. However, employment of diverse electrophoresis techniques across laboratories has resulted in inconsistent allele sizes, creating doubts about the suitability of the assay. This study evaluated agarose gel electrophoresis, slab gel electrophoresis, and capillary electrophoresis techniq...
متن کاملMicrofluidics for flow cytometric analysis of cells and particles.
This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvement of other components, replacement of conventional glass capillary-based fluid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 45 11 شماره
صفحات -
تاریخ انتشار 1999