Late Development of a Bronchocutaneous Fistula due to an Epicardial Cardioverter-Defibrillator Lead

نویسندگان

  • Vasileios Patris
  • Orestis Argiriou
  • Niki Lama
  • Haris Georgiou
  • Constantine Halkias
  • Christos Charitos
چکیده

Cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. We report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. Bronchoscopical investigation proved the existence of the fistula, which connected the epicardium, the left main bronchus, and the aforementioned site of skin infection. The patient refused an operation for the complete removal of the epicardial defibrillator and was treated conservatively. This case demonstrated that the long-term presence of foreign bodies in the epicardium may cause serious complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Myopotential oversensing notified by Lead Integrity Alert in a patient with implantable cardioverter defibrillator with a dedicated bipolar epicardial sensing lead

Although myopotential oversensing by a dedicated bipolar lead is rare, an epicardial lead on a dilated ventricle might contribute to its sensitivity. Myopotential oversensing was notified by the Lead Integrity Alert in this case. We should be aware of this possibility for the management of such patients.

متن کامل

Conservative Management of Skin Fistula Occurring After Internal Cardioverter Defibrillator Replacement

Skin fistula occurring after cardiac electronic device implantation is frequently related to pocket infection and this condition typically requires removal of device and lead(s). We report on a case of skin fistula occurring 3 weeks after internal cardioverter defibrillator replacement. Conservative management consisted of local care along with oral antibiotics without removal of device; this s...

متن کامل

Infections after cardioverter-defibrillator implantation: observations in 335 patients over 10 years.

OBJECTIVE To determine the incidence of infection after implantation of a cardioverter-defibrillator and the management of this complication. SUBJECTS 335 consecutive patients who had a cardioverter-defibrillator implanted between January 1984 and December 1993. MAIN OUTCOME MEASURES Incidence of infection within the first month after implantation (early infection) and after the first month...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015