Radiation dose and image quality of double-loaded cassettes.
نویسندگان
چکیده
Some U.S. hospitals double-load x-ray cassettes for certain procedures. Loading two films in the same cassette for portable emergency room (ER), intensive care unit (ICU), or operating room radiographs provides both the referring clinicians and the radiologists with immediate images. Our study demonstrates a cost increase of 15%, an increase in air kerma for a chest x ray from 0.12 to 0.35 mGy (12-35 mrad), slight differences in optical density, image contrast, and spatial resolution under double-loading conditions. Our study shows that double loading cassettes may improve patient care by economically expediting the communication of radiographic findings. The decision to double load portable ICU or ER cassettes must be based on a balance of factors.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملEvaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...
متن کاملA Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
متن کاملOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
متن کاملEfficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography
Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...