[Evaluation of anterior segment foreign bodies with ultrasound biomicroscopy].

نویسندگان

  • Marília Freitas de Moura
  • Ilka Hayashi
  • Daniel Martins Rocha
  • Norma Allemann
چکیده

INTRODUCTION Ocular trauma is considered a health care problem because is an important cause for visual impairment. Intraocular foreign bodies are related to activities involving usage of metallic objects, but other materials can be present in the eye and have to be diagnosed and localized. Ultrasound biomicroscopy is an adequate subsidiary tool to evaluate an anterior chamber intraocular foreign body. PURPOSE To characterize nature, localization, dimensions of foreign bodies and associated lesions to the anterior segment using ultrasound biomicroscopy. METHODS Retrospective clinical study of 7,182 patient's charts submitted to ultrasound biomicroscopy examination between 1999 and 2008, totalizing 59 eyes suspected of anterior segment foreign body. RESULTS Five cases presented two foreign bodies, fragments from the same nature, in different locations or not; and three cases had uncountable fragments in the anterior segment. Concerning localization: cornea, 11 (26%); conjunctiva, 10 (23%); iris, 10 (23%); lens, 9 (21%); sclera, 5 (12%); corneal angle, 5 (12%); ciliary body, 3 (7%). Among the associated lesions, it was identified: corneal perforation in 12 cases, corneal laceration in 2 cases, anterior synechia in 6 cases, traumatic aniridia 1 case, traumatic iridotomy in 3 cases, anterior chamber reaction in 10 cases and rupture of the anterior lens capsule in 4 cases. Considering composition: metallic, 21 (50%); non metallic, 20 were glass (48%) and 1 was vegetal (2%). The size of foreign bodies varied from 0.09 to 2.45 mm (average: 0.84 mm). CONCLUSIONS Ultrasound biomicroscopy is useful to localize foreign bodies in the anterior segment. This imaging method can give orientation about composition, path, and localization of foreign bodies and associated lesions, thus facilitating therapeutic planning prior to intervention, avoiding additional lesions to the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of ultrasound biomicroscopy (UBM) in the detection and localisation of anterior segment foreign bodies.

INTRODUCTION The aim of this study was to investigate the role of ultrasound biomicroscopy (UBM) in imaging anterior segment foreign bodies and compare it with conventional B-scan ultrasound and computed tomography (CT). MATERIALS AND METHODS The charts of 18 eyes with anterior segment foreign bodies were reviewed. The rates of detection of foreign bodies using ultrasound, CT scan and UBM wer...

متن کامل

Role of B-scan ultrasonography in the localization of intraocular foreign bodies in the anterior segment: a report of three cases

BACKGROUND The accurate localization of intraocular foreign bodies (IOFBs) is very important for the management of ocular trauma patients. B-scan ultrasonography is usually used to detect IOFBs in the posterior segment. Here, we report three cases with IOFBs in the anterior segment near the posterior lens capsule, which were accurately localized by B-scan ultrasonography under dynamic transvers...

متن کامل

A review of the role of ultrasound biomicroscopy in glaucoma associated with rare diseases of the anterior segment

Ultrasound biomicroscopy is a non-invasive imaging technique, which allows high-resolution evaluation of the anatomical features of the anterior segment of the eye regardless of optical media transparency. This technique provides diagnostically significant information in vivo for the cornea, anterior chamber, chamber angle, iris, posterior chamber, zonules, ciliary body, and lens, and is of gre...

متن کامل

Changing Trends of Imaging in Angle Closure Evaluation

Primary angle closure glaucoma (PACG) is a significant cause of visual disability worldwide. It predominantly affects the Eastern and South Asian population of the world. Early detection of anatomically narrow angles is important, and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). Gonioscopy has given way to modern day i...

متن کامل

Anterior segment implantation cysts. Ultrasound biomicroscopy with histopathologic correlation.

OBJECTIVE To correlate the clinical, histopathologic, and ultrasound biomicroscopic characteristics of anterior segment implantation cysts. METHODS We performed a retrospective review of 7 cases of secondary anterior segment implantation cysts. We reviewed the clinical history, visual acuity, clinical findings, and ultrasound biomicroscopic characteristics in all cases. Histopathologic correl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 75 2  شماره 

صفحات  -

تاریخ انتشار 2012