An all-reflective computed tomography imaging spectrometer

نویسندگان

  • William R. Johnson
  • Daniel W. Wilson
  • Greg Bearman
  • Johan Backlund
چکیده

The computed tomographic imaging spectrometer (CTIS) is a passive non-scanning instrument which simultaneously records a scenes spectral content as well as its 2-D spatial. Simultaneously implies a time frame limited only by the frame rate and signal-to-noise of the imaging device. CTIS accomplishes this by feeding incident scene radiation through a computer generated hologram (CGH) in Fourier space. The resulting dispersion pattern is recorded on a conventional pixilated imager and is stored on a local computer for post processing using iterative reconstruction techniques. A virtual 3-D datacube is constructed with one dimension in terms of energy weights for each wavelength band. CTIS is ideal for observing rapidly varying targets and has found use in military, bio-medical and astronomical applications. For the first time we have built an entirely reflective design based on the popular Offner reflector using a computer generated hologram formed on a convex mirror surface. Furthermore, a micro electro-mechanical system (MEMS) has been uniquely incorporated as a dynamic field stop for smart scene selection. Both the MEMS and reflective design are discussed. The CTIS multiplexes spatial and spectral information, so the two quantities are interdependent and adjustments must be made to the design in order to allow adequate sampling for our given application. Optical aberrations arising from a tilted image plane are alleviated through design optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

Staging of Laryngeal and Hypopharyngeal Cancer: Computed Tomography versus Histopathology

Introduction: Computed tomography (CT) imaging is the choice of investigation for evaluation of extent of tumor under the mucosa, locally and regionally. This study was undertaken to assess the accuracy of preoperative CT imaging in the staging of carcinoma of the larynx and hypopharynx.   Materials and Methods: In this retrospective study, all cases who were clinically (c) staged T3–T4 and w...

متن کامل

Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004