Power-free sequential injection for microchip immunoassay toward point-of-care testing.

نویسندگان

  • Kazuo Hosokawa
  • Masaki Omata
  • Kae Sato
  • Mizuo Maeda
چکیده

This paper presents a simple fluid handling technique for microchip immunoassay. Necessary solutions were sequentially injected into a microchannel by air-evacuated poly(dimethylsiloxane), and were passively regulated by capillary force at the inlet opening. For heterogeneous immunoassay, microchips are potentially useful for reduction of sample consumption and assay time. However, most of the previously reported microchips have limitations in their use because of the needs for external power sources for fluid handling. In this paper, an on-chip heterogeneous immunofluorescence assay without such an external power source is demonstrated. The microchip consisting of poly(dimethylsiloxane) (PDMS) and glass has a simple structure, and therefore is suitable for single-use applications. Necessary solutions were sequentially injected into a microchannel in an autonomous fashion with the power-free pumping technique, which exploits the high solubility and the rapid diffusion of air in PDMS. For deionized water, this method yielded flow rates of 3-5 nL s-1 with reproducibility of 4-10%. The inlet opening of the microchannel functioned as a passive valve to hold the solution when the flow was finished. Rabbit immunoglobulin G (rIgG) and human C-reactive protein (CRP) were detected using the microchannel walls as reaction sites. With the sample consumption of 1 microL and the assay time of approximately 20 min including the antibody immobilization step, the sandwich immunoassay methods for rIgG and CRP exhibited the limits of detection of 0.21 nM (0.21 fmol) and 0.42 nM (0.42 fmol), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power-free microchip immunoassay of PSA in human serum for point-of-care testing.

For point-of-care testing (POCT), a sandwich-typed immunoassay on poly(dimethylsiloxane) (PDMS) microfluidic chips was developed by employing two original technologies: a power-free microchip and laminar flow-assisted dendritic amplification (LFDA). Sequential injection of reagents of immunoassay was carried out by the power-free microchip. In addition, for the amplification of a fluorescent si...

متن کامل

Development of a microchip Europium nanoparticle immunoassay for sensitive point-of-care HIV detection.

Rapid, sensitive and specific diagnostic assays play an indispensable role in determination of HIV infection stages and evaluation of efficacy of antiretroviral therapy. Recently, our laboratory developed a sensitive Europium nanoparticle-based microtiter-plate immunoassay capable of detecting target analytes at subpicogram per milliliter levels without the use of catalytic enzymes and signal a...

متن کامل

Field effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices

The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...

متن کامل

SUB-ATTOMOLE DETECTION OF MicroRNA IN TWENTY MINUTES USING POWER-FREE MICROFLUIDIC CHIP: TOWARDS POINT-OF-CARE TESTING

This paper reports the first achievement in sub-attomole microRNA detection on the microfluidic device realized by laminar flow-assisted dendritic amplification (LFDA). This method allows us to detect microRNA at a limit of detection of 0.5 pM from 0.5 μL sample solution, which corresponds to 0.25 attomole, with the detection time of 20 min. Since some miRNAs circulating in blood have been foun...

متن کامل

Effect of Direct Injection Diesel Engine Convert to Sequential Injection CNG Engine in Intake Port Gas Flow Pressure Profile

The one dimension computational model of a sequential injection engine, which runs on compressed natural gas (CNG) with spark ignition, is developed for this study, to simulate the performance of gas flow pressure profile, under various speed conditions. The computational model is used to simulate and study of the steady state and transient processes of the intake manifold. The sequential injec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2006