Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records.

نویسندگان

  • Renda Soylemez Wiener
  • Lisa M Schwartz
  • Steven Woloshin
  • H Gilbert Welch
چکیده

BACKGROUND Because pulmonary nodules are found in up to 25% of patients undergoing computed tomography of the chest, the question of whether to perform biopsy is becoming increasingly common. Data on complications after transthoracic needle lung biopsy are limited to case series from selected institutions. OBJECTIVE To determine population-based estimates of risks for complications after transthoracic needle biopsy of a pulmonary nodule. DESIGN Cross-sectional analysis. SETTING The 2006 State Ambulatory Surgery Databases and State Inpatient Databases for California, Florida, Michigan, and New York from the Healthcare Cost and Utilization Project. PATIENTS 15 865 adults who had transthoracic needle biopsy of a pulmonary nodule. MEASUREMENTS Percentage of biopsies complicated by hemorrhage, any pneumothorax, or pneumothorax requiring a chest tube, and adjusted odds ratios for these complications associated with various biopsy characteristics, calculated by using multivariate, population-averaged generalized estimating equations. RESULTS Although hemorrhage was rare, complicating 1.0% (95% CI, 0.9% to 1.2%) of biopsies, 17.8% (CI, 11.8% to 23.8%) of patients with hemorrhage required a blood transfusion. In contrast, the risk for any pneumothorax was 15.0% (CI, 14.0% to 16.0%), and 6.6% (CI, 6.0% to 7.2%) of all biopsies resulted in pneumothorax requiring a chest tube. Compared with patients without complications, those who experienced hemorrhage or pneumothorax requiring a chest tube had longer lengths of stay (P < 0.001) and were more likely to develop respiratory failure requiring mechanical ventilation (P = 0.020). Patients aged 60 to 69 years (as opposed to younger or older patients), smokers, and those with chronic obstructive pulmonary disease had higher risk for complications. LIMITATIONS Estimated risks may be inaccurate if coding of complications is incomplete. The analyzed databases contain little clinical detail (such as information on nodule characteristics or biopsy pathology) and cannot indicate whether performing the biopsy produced useful information. CONCLUSION Whereas hemorrhage is an infrequent complication of transthoracic needle lung biopsy, pneumothorax is common and often necessitates chest tube placement. These population-based data should help patients and physicians make more informed choices about whether to perform biopsy of a pulmonary nodule. PRIMARY FUNDING SOURCE Department of Veterans Affairs and National Cancer Institute.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of flexible bronchoscopy in non-resolving community-acquired pneumonia - A retrospective analysis.

20-gauge coaxial cutting needle. Clin Radiol. 2000;55: 281--7. 3. Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229:475--81. 4. Dennie CJ, Matzinger FR, Marriner JR, Maziak DE. Transthoracic needle biopsy of the lung: results of early discharge in 506 outpati...

متن کامل

Delayed presentation of cerebellar and spinal cord infarction as a complication of computed tomography-guided transthoracic lung biopsy: a case report

INTRODUCTION Computed tomography-guided transthoracic needle biopsy is a common diagnostic procedure that is associated with various complications including pneumothorax, parenchymal hemorrhage, and hemoptysis. A systemic air embolism is a very rare (0.06 to 0.21%) but potentially fatal complication. CASE PRESENTATION A 70-year-old Korean male was admitted to our hospital for evaluation of a ...

متن کامل

تعیین ارزش تشخیصی بیوپسی سوزنی ترانس توراسیک با راهنمایی سونوگرافی در تشخیص توده‌های محیطی ریه

Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...

متن کامل

Advances in imaging of the solitary pulmonary nodule.

OBJECTIVE To review the radiological management of a solitary pulmonary nodule. DATA SOURCES MEDLINE literature search (1958-2002). STUDY SELECTION All review articles and original articles. Key words for the literature search were 'solitary pulmonary nodule' and 'imaging'. DATA EXTRACTION All relevant information and data. DATA SYNTHESIS The solitary pulmonary nodule remains a perennia...

متن کامل

Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules

To evaluate the diagnostic accuracy of computed tomography (CT)-guided percutaneous lung biopsy for solitary pulmonary nodules. Three hundred and eleven patients (211 males and 100 females), with a mean age of 59.6 years (range, 19-87 years), who were diagnosed with solitary pulmonary nodules and underwent CT-guided percutaneous transthoracic needle biopsy between January 2008 and January 2014 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of internal medicine

دوره 155 3  شماره 

صفحات  -

تاریخ انتشار 2011