Glaucoma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation.

نویسندگان

  • Asher Weiner
  • Aaron D Cohn
  • Mamtha Balasubramaniam
  • Adam J Weiner
چکیده

PURPOSE To summarize our clinical experience with implanting Baerveldt glaucoma tube shunts through the ciliary sulcus in eyes with a posterior chamber intraocular lens and shallow anterior chambers, corneal transplants, guttata or edema. PATIENTS AND METHODS A retrospective interventional nonrandomized noncomparative case series. Main outcome measure was postoperative corneal status. Secondary outcome measures included postoperative intraocular pressure (IOP), visual acuity and complications. RESULTS Thirty-six eyes of 32 patients were identified through chart review. Follow-up period was 21.8+/-16.6 months (mean+/-standard deviation, range: 4.0 to 58.5 mo). At final visit, all 23 preoperative clear native corneas and 6 of 7 corneal transplants remained clear. Thus, of the 30 preoperative clear corneas, only 1 decompensated. Preoperative IOP was 27.9+/-11.8 mm Hg (range: 12 to 59 mm Hg), reduced postoperatively to 10.1+/-3.9 mm Hg (range: 2 to 21 mm Hg, P=0.0001), a reduction of 58.2%+/-19.3% (range: 5.0% to 95.4%). Final IOP was >or=5 and <or=21 mm Hg in 33 of 36 eyes (91.7%). It was lowered by 30% or more in 34 of 36 eyes (94.4%). CONCLUSIONS Although previously published studies demonstrated a significant risk of corneal decompensation after angle or pars plana tube implantation, our clinical experience suggests that ciliary sulcus tube implantation in eyes with a posterior chamber intraocular lens is a safe and effective procedure even in eyes with high risk of corneal decompensation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ahmed glaucoma valves in refractory glaucoma: a 7-year audit.

PURPOSE To present the long-term results of Ahmed glaucoma valve (AGV) implantation. METHODS Consecutive case series of 94 eyes with AGV implantation over 7 years. Temporary tube ligation with C3F8 gas fill was used in high-risk eyes (group G&L) and compared with standard implantation in both phakic (group A) and pseudophakic/aphakic eyes (group B). Success was intraocular pressure (IOP) of 6...

متن کامل

The long-term anterior segment configuration after pediatric cataract surgery and the association with secondary glaucoma

Secondary glaucoma constitutes major sight-threatening complication of pediatric cataract surgery, yet the etiology remains unclear. The purpose of this study was to investigate the long-term anterior segment configuration and the association with secondary glaucoma in pediatric pseudophakia. Ultrasound biomicroscopy (UBM) was performed on 40 eyes of 26 children underwent pediatric cataract sur...

متن کامل

Complications of Baerveldt glaucoma drainage implants.

OBJECTIVES To report the incidence and identify risk factors of postoperative complications after Baerveldt glaucoma drainage implantation. METHODS A retrospective review of the medical records of all patients at the Bascom Palmer Eye Institute, Miami, Fla, who underwent placement of a Baerveldt glaucoma drainage implant from October 1, 1992, through October 31, 1996, to determine demographic...

متن کامل

Glaucoma and Corneal Decompensation Following Cosmetic Iris Prosthesis Implantation: A Case Report

Purpose: This case report illustrates the difficult management of complications produced following the bilateral iris implant of the NewColorIris (NewColorIris, Kahn, and Medical Devices. Methods: We report the case of a 36-year-old man who was referred to our outpatient clinic because of bilateral glaucoma showing a poor response to medical treatment and anti-glaucoma surgery. The young man ha...

متن کامل

Review of the Ahmed versus Baerveldt study—5-year treatment outcomes

The results from the tube versus trabeculectomy (TVT) study provided the evidence to support the use of aqueous shunt surgery and its increasing popularity in the world. The Ahmed versus Baerveldt (AVB) study, a randomized controlled study, compared the efficacy and safety between two of the most commonly used glaucoma drainage implants. A significant proportion of the participants had failed t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2010