Variational Denoising of Diffusion Weighted Mri

نویسندگان

  • Tim McGraw
  • Baba Vemuri
  • Evren Ozarslan
  • Yunmei Chen
  • Thomas Mareci
  • Luminita Vese
چکیده

In this paper, we present a novel variational formulation for restor­ ing high angular resolution diffusion imaging (HARDI) data. The restoration formulation involves smoothing signal measurements over the spherical do­ main and across the 3D image lattice. The regularization across the lattice is achieved using a total variation (TV) norm based scheme, while the finite ele­ ment method (FEM) was employed to smooth the data on the sphere at each lattice point using first and second order smoothness constraints. Examples are presented to show the performance of the HARDI data restoration scheme and its effect on fiber direction computation on synthetic data, as well as on real data sets collected from excised rat brain and spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Smoothing & Estimation of DTI via Robust Variational Non-local Means

Regularized diffusion tensor estimation is an essential step in DTI analysis. There are many methods proposed in literature for this task but most of them are neither statistically robust nor feature preserving denoising techniques that can simultaneously estimate symmetric positive definite (SPD) diffusion tensors from diffusion MRI. One of the most popular techniques in recent times for featu...

متن کامل

Non-Local Means Variants for Denoising of Diffusion-Weighted and Diffusion Tensor MRI

Diffusion tensor imaging (DT-MRI) is very sensitive to corrupting noise due to the non linear relationship between the diffusion-weighted image intensities (DW-MRI) and the resulting diffusion tensor. Denoising is a crucial step to increase the quality of the estimated tensor field. This enhanced quality allows for a better quantification and a better image interpretation. The methods proposed ...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Denoising of complex MRI data by wavelet-domain filtering: application to high-b-value diffusion-weighted imaging.

The Rician distribution of noise in magnitude magnetic resonance (MR) images is particularly problematic in low signal-to-noise ratio (SNR) regions. The Rician noise distribution causes a nonzero minimum signal in the image, which is often referred to as the rectified noise floor. True low signal is likely to be concealed in the noise, and quantification is severely hampered in low-SNR regions....

متن کامل

Adaptive diffusion constrained total variation scheme with application to 'cartoon + texture + edge' image decomposition

We consider an image decomposition model involving a variational (minimization) problem and an evolutionary partial differential equation (PDE). We utilize a linear inhomogenuous diffusion constrained and weighted total variation (TV) scheme for image adaptive decomposition. An adaptive weight along with TV regularization splits a given image into three components representing the geometrical (...

متن کامل

Simultaneous Denoising and Registration for Accurate Cardiac Diffusion Tensor Reconstruction from MRI

Cardiac diffusion tensor MR imaging (DT-MRI) allows to analyze 3D fiber organization of the myocardium which may enhance the understanding of, for example, cardiac remodeling in conditions such as ventricular hypertrophy. Diffusion-weighted MRI (DW-MRI) denoising methods rely on accurate spatial alignment of all acquired DW images. However, due to cardiac and respiratory motion, cardiac DT-MRI ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009