Limits to progressive reduction of resident skin bacteria by disinfection.
نویسندگان
چکیده
Antiseptic preparations used repeatedly to disinfect the skin caused a reduction in yield of resident flora to a low equilibrium level beyond which further reduction did not occur. This equilibrium varied with the antiseptic preparation used. In a comparison of three preparations, the lowest equilibrium level was obtained with 95% ethyl alcohol. The further reduction in yield of skin bacteria on using alcohol after repeated disinfection with an antiseptic detergent preparation ('two-phase' disinfection) was not paralleled by a further reduction when the preparations used in the two phases were reversed, the antiseptic detergent being used after repeated disinfection with ethyl alcohol. 'Two-phase' disinfection was therefore seen to be due to further reduction in skin bacteria from the low equilibrium obtained with the antiseptic detergent to the lower level obtainable by alcohol disinfection. When repeated disinfection to equilibrium with alcohol was followed by a 'second-phase' handwash with a non-antiseptic detergent and water, there was a large increase in the yield of skin bacteria. This finding supports the view that a low equilibrium level occurs when the reduction in density of accessible bacteria through disinfection is balanced by the emergence of bacteria drawn from deeper layers of the skin.
منابع مشابه
Skin disinfection and acupuncture.
The need for skin disinfection before insertion of an acupuncture needle is controversial and there is no specific research on this topic. However research and observations on the effect of, and the need for, skin disinfection before injections forms a good analogy of acupuncture. Whilst micro-organisms present on the surface of the skin are accessible to disinfection, those located under the s...
متن کاملPulsed electric fields for burn wound disinfection in a murine model.
Emerging bacterial resistance renders many antibiotics ineffective, making alternative strategies of wound disinfection important. Here the authors report on a new, physical burn wound disinfection method: pulsed electric fields (PEFs). High voltage, short PEFs create nonthermal, permanent damage to cell membranes, possibly by irreversible electroporation. In medicine, PEF technology has recent...
متن کاملDisinfection of the skin with detergent preparations of Irgasan DP 300 and other antiseptics.
An evaluation of the relative effectiveness of 2% hexachlorophane and 0.75% Irgasan DP 300 bar soaps in disinfection of the hands showed that the former caused a significantly larger reduction in natural skin bacteria than the latter after one handwash and after six handwashings, three on each of two successive days. Repeated use of Irgasan DP 300 bar soap caused a significantly greater reducti...
متن کاملAntibacterial Activity of Germicide-P : A Persulfate Based Detergent/Disinfectant on Some Hospital Isolates
A novel chemical detergent/disinfectant formulated based on persulfate salts, germicide P , is available for disinfection of surfaces and medical devices at the room temperature. Because of the resistance of hospital-resident microorganisms, the antimicrobial activity of this compound is evaluated in the present study. The tests conducted with this disinfectant included bactericidal tests ...
متن کاملSkin disinfection in preterm infants.
Greater care and a more thorough approach to intravenous catheter site disinfection may be important for the prevention of catheter related sepsis, especially with coagulase negative staphylocci in preterm infants. The efficacy of skin disinfection was evaluated in preterm infants using a skin swabbing technique after disinfectant exposure. In the first part of the study, 25 peripheral intravas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 32 4 شماره
صفحات -
تاریخ انتشار 1979