Dextran and hydroxyethyl starch do not interfere with fibrinogen measurement if Clauss method with mechanical clot detection is used
نویسندگان
چکیده
bleeding following major trauma, published in a recent issue of Critical Care, Rossaint and colleagues [1] recommended that thrombelastometry instead of other laboratory methods be used to measure fi brinogen. Th e authors stated that the Clauss method [2] overestimates fi brino gen concentration when colloids are given. Th is claim is supported by studies of patients receiving colloids in which fi brinogen was measured by an automated Clauss assay performed on an ACL-300R coagulometer (Instrumentation Laboratory, Bedford, MA, USA), which detects clot formation photo-optically [3]. Automated coagulometers use diff erent technologies to detect fi brin clot endpoints. Some coagulometers employ mechanical principles involving the movement of a metal hook or the clot impedance of a ball bearing in a magnetic fi eld; others use photo-optical devices to measure changes in light transmission [2]. Recently, Adam and colleagues [4] analyzed plasma diluted with diff erent proportions of saline or hydroxyethyl starch (HES). Fibrinogen concentration was overestimated if the clotting time was measured photooptically in samples diluted with HES. But fi brinogen measurements in analyzers that used mechanical clot detection endpoints were accurate. Fenger-Eriksen and colleagues [5] assessed the accuracy of fi brinogen measure ments in diff erent analyzers and diff erent methods in plasma diluted in diff erent proportions with saline, HES, and albumin. Th e authors found that the photo-optical measurement overestimated fi brinogen concentration but that mechanical detection did not. Th romboelastometry seems to be a rapid and accurate estimation of the level and function of fi brinogen but is not available in most centers. However, most laboratories can easily measure fi brinogen by the Clauss method using mechanical detection. We recommend that the European guidelines specifying the use of thromboelastometry over the Clauss method be revised and qualifi ed accordingly.
منابع مشابه
Free oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII concentrates
BACKGROUND Haemodilution and hypothermia induce coagulopathy separately, but their combined effect on coagulation has not been widely studied. Fibrinogen concentrate can correct dilutional coagulopathy and has an additional effect when combined with factor XIII concentrate. However, their effect on dilutional coagulopathy concomitant with hypothermia has not been studied previously. Free oscill...
متن کاملFree oscillation rheometry monitoring of haemodilution and hypothermia and correction with fibrinogen and factor XIII
Background: Haemodilution and hypothermia induce coagulopathy separately, but their combined effect on coagulation has not been widely studied. Fibrinogen concentrate can correct dilutional coagulopathy and has an additional effect when combined with factor XIII concentrate. However, their effect on dilutional coagulopathy concomitant with hypothermia has not been studied previously. Free oscil...
متن کاملAlbumin-induced coagulopathy is less severe and more effectively reversed with fibrinogen concentrate than is synthetic colloid-induced coagulopathy
BACKGROUND Synthetic colloids cause dilutional coagulopathy. The aims of our study were to determine whether the natural colloid albumin induces a lesser degree of coagulopathy compared to synthetic colloids, and the comparative effectiveness of fibrinogen concentrate to reverse coagulopathy following dilution with these solutions. METHODS Coagulation was assessed with rotational thrombelasto...
متن کاملExpressiveness of global coagulation parameters in dilutional coagulopathy.
BACKGROUND Plasma-free volume replacement in haemorrhage often results in dilutional coagulopathy. Prothrombin time index (PTI) and activated partial thromboplastin time (aPTT) are used for monitoring haemostasis but have not yet been clinically evaluated. Our aim was to investigate the effects of haemodilution on the course of global coagulation tests and clotting factors (CFs). METHODS Bloo...
متن کاملEffect of hydroxyethyl starch on acidosis in patients with aluminum phosphide poisoning
Background: Given the fact that various studies have reported the positive effects of hydroxyethyl starch therapy in controlling shock, this study aimed to compare the effects of hydroxyethyl starch on modifying acidosis and treating patients with aluminum phosphide poisoning. Methods: This was a randomized clinical trial that was conducted on 60 patients with aluminum phosphide poisoning. We ...
متن کامل