Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia.

نویسندگان

  • Reuven Pizov
  • Arieh Eden
  • Dmitri Bystritski
  • Elena Kalina
  • Ada Tamir
  • Simon Gelman
چکیده

BACKGROUND Respiratory-induced arterial and plethysmographic (pulse oximetry) waveform changes were shown to be good predictors of cardiac output response to increased preload. The aim of this study was to evaluate the reliability of arterial and plethysmographic waveform variables in patients with mild hypovolemia. METHODS Patients undergoing autologous hemodilution were studied. After anesthesia induction, hemodilution was performed by withdrawing blood in steps of 2% of estimated circulating blood volume (ECBV), up to 20%. The patients who did not develop hypotension (systolic blood pressure < 80 mmHg) were studied. Arterial and plethysmographic waveforms were recorded and analyzed off-line at baseline and after each withdrawal of blood. Variations in arterial systolic and pulse pressure were analyzed using standard methods. Plethysmographic waveform variation and delta pulse oximetry plethysmography were determined by using pulse oximetry recordings. RESULTS There were 33 study participants. Systolic blood pressure decreased by 11%, and heart rate increased from 73 to 76 beats/min after a 20% reduction of ECBV. Systolic pressure and pulse pressure variations increased (P < 0.005) after a 4% reduction of ECBV. The values of arterial pressure and pulse oximetry waveform variables almost doubled in value after a 20% reduction of ECBV. Systolic pressure variation was the most reliable variable during hypovolemia. Plethysmographic waveform variation increased significantly after a 6% reduction of ECBV and delta pulse oximetry plethysmography after an 8% reduction of ECBV. CONCLUSIONS Arterial and pulse oximetry respiratory-induced changes in waveform variables are reliable indicators of mild hypovolemia in anesthetized patients. The pulse oximetry plethysmographic waveforms accurately reflect arterial waveforms during more progressive hypovolemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between respiratory pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure variations among patients with and without norepinephrine use.

OBJECTIVES Arterial pulse pressure respiratory variation is a good predictor of fluid response in ventilated patients. Recently, it was shown that respiratory variation in arterial pulse pressure correlates with variation in pulse oximetry plethysmographic waveform amplitude. We wanted to evaluate the correlation between respiratory variation in arterial pulse pressure and respiratory variation...

متن کامل

Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients

INTRODUCTION Respiratory variation in arterial pulse pressure is a reliable predictor of fluid responsiveness in mechanically ventilated patients with circulatory failure. The main limitation of this method is that it requires an invasive arterial catheter. Both arterial and pulse oximetry plethysmographic waveforms depend on stroke volume. We conducted a prospective study to evaluate the relat...

متن کامل

Hypotension during gradual blood loss: waveform variables response and absence of tachycardia.

BACKGROUND Variation in arterial pressure and plethysmographic waveforms has been shown to be predictors of cardiac output response to fluid challenge. The objective of this study was to evaluate the ability of arterial and plethysmographic waveform variables to predict hypotension during blood loss. METHODS Patients undergoing autologous haemodilution were studied. After anaesthesia inductio...

متن کامل

Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic volunteers.

BACKGROUND The primary objective of this study was to determine whether alterations in the pulse oximeter waveform characteristics would track progressive reductions in central blood volume. We also assessed whether changes in the pulse oximeter waveform provide an indication of blood loss in the hemorrhaging patient before changes in standard vital signs. METHODS Pulse oximeter data from fin...

متن کامل

Clinical investigation of plethysmographic variability index: A derivative index of pulse oximetry in anesthetized dogs

Paranjape, Vaidehi V. M.S., Purdue University, August 2014. Clinical Investigation of Plethysmographic Variability Index: A Derivative Index of Pulse Oximetry in Anesthetized Dogs. Major Professor: Jeff C. Ko. Plethysmographic Variability Index (PVI) is a derivative index of pulse oximetry that allows evaluating an individual's intravascular volume status. Perfusion Index (PI) represents the st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 113 1  شماره 

صفحات  -

تاریخ انتشار 2010