Diagnostic underestimation of atypical ductal hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution*

نویسندگان

  • Gustavo Machado Badan
  • Decio Roveda Júnior
  • Sebastião Piato
  • Eduardo de Faria Castro Fleury
  • Mário Sérgio Dantas Campos
  • Carlos Alberto Ferreira Pecci
  • Felipe Augusto Trocoli Ferreira
  • Camila D'Ávila
چکیده

OBJECTIVE To determine the rates of diagnostic underestimation at stereotactic percutaneous core needle biopsies (CNB) and vacuum-assisted biopsies (VABB) of nonpalpable breast lesions, with histopathological results of atypical ductal hyperplasia (ADH) or ductal carcinoma in situ (DCIS) subsequently submitted to surgical excision. As a secondary objective, the frequency of ADH and DCIS was determined for the cases submitted to biopsy. MATERIALS AND METHODS Retrospective review of 40 cases with diagnosis of ADH or DCIS on the basis of biopsies performed between February 2011 and July 2013, subsequently submitted to surgery, whose histopathological reports were available in the internal information system. Biopsy results were compared with those observed at surgery and the underestimation rate was calculated by means of specific mathematical equations. RESULTS The underestimation rate at CNB was 50% for ADH and 28.57% for DCIS, and at VABB it was 25% for ADH and 14.28% for DCIS. ADH represented 10.25% of all cases undergoing biopsy, whereas DCIS accounted for 23.91%. CONCLUSION The diagnostic underestimation rate at CNB is two times the rate at VABB. Certainty that the target has been achieved is not the sole determining factor for a reliable diagnosis. Removal of more than 50% of the target lesion should further reduce the risk of underestimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous biopsy in radiological imaging of the breast

Radiol Bras. 2016 Mar/Abr;49(2):IX The article “Diagnostic underestimation of atypical hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution”, published in the previous issue of Radiologia Brasileira, was produced at a referral teaching institution and reflects the level of responsibility required in ...

متن کامل

Sonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods

OBJECTIVE To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on ...

متن کامل

Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

PURPOSE To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). MATERIALS AND METHODS Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guide...

متن کامل

Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device.

BACKGROUND Percutaneous, vacuum-assisted, large-gauge core needle biopsy (VACNB) provides an alternative to open surgical biopsy as an initial diagnostic tool for breast lesions, yet rates of underestimating malignant diagnoses remain sufficiently high to warrant surgical biopsy in some cases. The current study was performed to determine if the Breast Lesion Excision System (BLES) provides a fe...

متن کامل

Diagnostic accuracy of vacuum-assisted stereotactic core needle biopsy for breast lesions.

OBJECTIVE To evaluate the diagnostic accuracy of the vacuum-assisted stereotactic core needle biopsy (CNB) for breast lesions. MATERIAL AND METHOD Sixty-four lesions that had undergone vacuum-assisted stereotactic CNB between January 2003 and December 2005 in Ramathibodi Breast diagnostic center were included in this study. Pathologic results of CNB were reviewed and correlated with pathologi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2016