Comparison of two types of biomecanics for deep overbite correction

نویسنده

  • Ana de Lourdes Sá de Lira
چکیده

Aim: To compare two types of treatment for Class II deep overbite malocclusion assessing maxillary and mandibular arches behavior in subjects submitted to full orthodontic treatment with standard edgewise appliance and those who used straight wire appliance. Methods: The sample consisted of 50 patients treated with full fixed appliances either with edgewise appliance (n=25, Group 1), or with straight wire appliance (n=25, Group 2). In both groups lateral cephalometric radiographs were compared with those done at the beginning of treatment and at its end, in order to quantify the cephalometric measures (8 linear and 6 angular) presenting the maxillary and mandibular arches behavior in the anteroposterior and vertical directions. All patients were treated without extraction or use of Class II intermaxillary elastics during the full orthodontic treatment. Results: In both groups the treatment of malocclusion contributed for mandibular forward displacement, reduction of deep overbite and overjet, reduction of mandibular plane with anti-clockwise rotation and labial projection of maxillary incisors. Conclusions: In both groups the sample showed favorable mandibular displacement, reduction of facial convexity, and profile improvement with anti-clockwise rotation. The correction of deep overbite was due to labial projection and intrusion of maxillary incisors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Skeletodental Changes Occurring during Deep Overbite Correction with Mini-Implant Anchorage System

Deep overbite has potentially detrimental effects on mandibular and temporomandibular joint function and periodontal health as well as esthetics. Incisor intrusion can be achieved with various treatment modalities. The most commonly used is the utility arch technique. In mini-implant anchorage system, forces can be applied to produce tooth movement in any direction without detrimental reciproca...

متن کامل

The effectiveness and long-term stability of overbite correction with incisor intrusion mechanics.

BACKGROUND Correction of deep overbite with subsequent achievement of long-term stability is difficult. The purpose of this study was to investigate the effectiveness and long-term stability of overbite correction with incisor intrusion mechanics. METHODS The treated group consisted of 25 subjects (13 female, 12 male) with deep overbite of at least 4 mm (mean overbite, 5.9 mm). The orthodonti...

متن کامل

Class II malocclusion with deep overbite: A sequential approach

Objective: The aim of this case report was to evaluate the results of deep overbite correction by the segmented arch technique. Methods: The first stage of the treatment was performed with this technique to intrude incisors and canines. A maxillary transpalatal bar and a mandibular lingual arch using 0.051-in archwire were employed associated to a facial bow, anchored primarily with occipital p...

متن کامل

Correction of deep bite in adults using the Invisalign system.

719 D overbite is commonly treated by molar extrusion, incisor intrusion, or both. Careful diagnostic assessment is needed to determine the best treatment approach. Patients with structural deep bites may require orthognathic surgery for full correction. The amount of incisor exposure in smiling is an important consideration in deep-bite cases. When the maxillary incisor display is correct, max...

متن کامل

Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II Division 2 patient.

A boy, aged 10.5 years, with a Class II molar relationship and a very deep overbite, complaining of a gummy smile and anterior crowding, was treated nonextraction with a mini-implant and Twin-block and edgewise fixed appliances. Severely extruded and retroclined maxillary incisors were intruded and proclined with a nickel-titanium closed-coil spring anchored to a mini-implant and segmented wire...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015