Analytical performance of the serum free light chain assay.

نویسندگان

  • Pierre-Yves Briand
  • Olivier Decaux
  • Hélène Caillon
  • Bernard Grosbois
  • André Le Treut
  • Lucienne Guenet
چکیده

BACKGROUND The Freelite system for nephelometric or turbidimetric measurement of serum free light chains (FLCs) has been available since 2001. It has been valuable for the management of patients with oligosecretory myeloma, light chain myeloma and AL amyloidosis. However, there are several limitations of the method. The goal of this study was to evaluate the analytical performance of the FLC assay. METHODS Titrated controls and clinical serum specimens were used to determine precision and post-dilution recovery. RESULTS As reported elsewhere, we found that the assay had several limitations, including poor post-dilution linearity and overestimation by nephelometry. CONCLUSIONS These data demonstrate that the results of the FLC assay must be interpreted jointly by the clinician and the biologist, taking into account the individual patient's clinical and biological characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum Free Light-chain Assay for the Diagnosis, Management, and Prognosis of Multiple Myeloma

In recent decades, new serum biomarkers have been developed for routine laboratory practice, such as assaying serum free light chains and more recently, assaying immunoglobulin heavy and light chain isotypes (Hevylite). In this work, we highlight the interest of new biomarkers (Hevylite Test) in the management of monoclonal gammopathies because of the technical advantages it confers and the se...

متن کامل

Practical considerations for the measurement of free light chains in serum.

BACKGROUND A new immunoassay for free light chain measurements has been reported to be useful for the diagnosis and monitoring of monoclonal light chain diseases and nonsecretory myeloma. We describe experience with and some potential pitfalls of the assay. METHODS The assay was assessed for precision, sample type and stability, recovery, and harmonization of results between two analyzers on ...

متن کامل

Development and characterization of polyclonal antibody against human kappa light chain in rabbit

Polyclonal antibodies against kappa light chain are used to diagnose diseases producing free light chain. The kappa and lambda light chains are products of immunoglobulin synthesis and released into the circulation in minor amounts such as serum, cerebrospinal fluid, urine and synovial fluid in normal condition. The purpose of this study was the production and purification of polyclonal immunog...

متن کامل

Serum free light chain assays not total light chain assays are the standard of care to assess Monoclonal Gammopathies.

The diagnosis of Multiple Myeloma is a challenge to the physician due to the non-specific symptoms (anemia, bone pain and recurrent infections) that are commonplace in the elderly population. However, early diagnosis is associated with less severe disease, including fewer patients presenting with acute renal injury, pathological fractures and severe anemia. Since 2006, the serum free light chai...

متن کامل

Questionable role of free light chain assay ratio to determine stringent complete remission in multiple myeloma patients.

We read with interest the Brief Report by Fernandez de Larrera investigating the role of abnormal serum free light chain ration in patients with complete remission. 1 The qualitative assay for free light chain has been reported to be sensitive and specific for detecting and monitoring diseases caused by monoclonal gammopa-thies, such as multiple myeloma. 2 More recently, the International Myelo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2010