Dmax for stereopsis depends on size, not spatial frequency content
نویسندگان
چکیده
Stereoacuity depends not only on the carrier frequency of Gabor stimuli, but also upon their size. To determine if this is also the case at large disparities, we have measured the upper limit for stereopsis, "Dmax", and assessed its dependence on carrier frequency and overall envelope size. The results differ markedly from the stereoacuity data. Dmax for stereopsis is primarily dependent on the size of the envelope of the Gabor patch, and is relatively independent of its carrier frequency. These results support the proposition that stereopsis is achieved at large disparities by way of non-linear processing (envelope extraction).
منابع مشابه
Differential binocular input and local stereopsis
Using fractal noise images, we measured the dependence of Dmin and Dmax for stereo on the interocular differences of spatial frequency and contrast. Dmin exhibits a strong dependence on the highest spatial frequency contained in the image, while Dmax exhibits a weaker dependence on the lowest spatial frequency contained within the image. Neither relationship was found to be different when the f...
متن کاملMonocular blur alters the tuning characteristics of stereopsis for spatial frequency and size
Our sense of depth perception is mediated by spatial filters at different scales in the visual brain; low spatial frequency channels provide the basis for coarse stereopsis, whereas high spatial frequency channels provide for fine stereopsis. It is well established that monocular blurring of vision results in decreased stereoacuity. However, previous studies have used tests that are broadband i...
متن کاملThe Spatial Limit for Motion Detection in Noise Depends on Element Size, not on Spatial Frequency
When a random spatial noise pattern is displaced for a short distance it seems to move coherently, but when the displacement exceeds a certain value, the direction of motion cannot be clearly perceived. We measured the displacement limit (Dmax) for a two-frame sequence and found that it depended on the size of the elements comprising the random pattern, even when low spatial frequencies were re...
متن کاملMotion detection is limited by element density not spatial frequency
Two-frame random-element kinematograms were used to study the matching algorithm employed by the visual system to keep track of moving elements. Previous data have shown that the maximum spatial displacement detectable (dmax) for random-dot kinematogram stimuli increases both with increasing dot size and with decreasing centre frequency for spatially band-pass kinematograms. Both of these findi...
متن کاملdmax for stereopsis and motion in random dot displays
The upper displacement limit for motion was compared with the upper disparity limit for stereopsis using two-frame random dot kinematograms or briefly presented stereograms. dmax (the disparity/displacement at which subjects make 20% errors in a forced-choice paradigm) was found to be very similar for motion and stereo at all dot densities, and to fall with increasing dot density (0.006% or two...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995