A comparison of three different VMAT techniques for the delivery of lung stereotactic ablative radiation therapy.
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to investigate coplanar and non-coplanar volumetric modulated arc therapy (VMAT) delivery techniques for stereotactic ablative radiation therapy (SABR) to the lung. METHODS For ten patients who had already completed a course of radiation therapy for early stage lung cancer, three new SABR treatment plans were created using (1) a coplanar full arc (FA) technique, (2) a coplanar partial arc technique (PA) and (3) a non-coplanar technique utilising three partial arcs (NCA). These plans were evaluated using planning target volume (PTV) coverage, dose to organs at risk, and high and intermediate dose constraints as incorporated by radiation therapy oncology group (RTOG) 1021. RESULTS When the FA and PA techniques were compared to the NCA technique, on average the PTV coverage (V 54Gy) was similar (P = 0.15); FA (95.1%), PA (95.11%) and NCA (95.71%). The NCA resulted in a better conformity index (CI) of the prescription dose (0.89) when compared to the FA technique (0.88, P = 0.23) and the PA technique (0.83, P = 0.06). The NCA technique improved the intermediate dose constraints with a statistically significant difference for the D 2cm and R 50% when compared with the FA (P < 0.03 and <0.0001) and PA (P < 0.04 and <0.0001) techniques. The NCA technique reduced the maximum spinal cord dose by 2.72 and 4.2 Gy when compared to the PA and FA techniques respectively. Mean lung doses were 4.09, 4.31 and 3.98 Gy for the FA, PA and NCA techniques respectively. CONCLUSION The NCA VMAT technique provided the highest compliance to RTOG 1021 when compared to coplanar techniques for lung SABR. However, single FA coplanar VMAT was suitable for 70% of patients when minor deviations to both the intermediate dose and organ at risk (OAR) constraints were accepted.
منابع مشابه
Comprehensive dosimetric planning comparison for early‐stage, non‐small cell lung cancer with SABR: fixed‐beam IMRT versus VMAT versus TomoTherapy
Volumetric-modulated arc therapy (VMAT) is emerging as a leading technology in treating early-stage, non-small cell lung cancer (NSCLC) with stereotactic ablative radiotherapy (SABR). However, two other modalities capable of deliver-ing intensity-modulated radiation therapy (IMRT) include fixed-beam and helical TomoTherapy (HT). This study aims to provide an extensive dosimetric compari-son amo...
متن کاملA dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non‐small cell lung cancer using stereotactic body radiotherapy
This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric-modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-fi...
متن کاملA treatment-planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric-modulated arc therapy
The purpose of this study was to determine appropriate beam arrangement for volumetric-modulated arc therapy (VMAT)-based stereotactic body radiation therapy (SBRT) in the treatment of patients with centrally located lung tumors. Fifteen consecutive patients with centrally located lung tumors treated at our institution were enrolled. For each patient, three VMAT plans were generated using two c...
متن کاملVolumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique
PURPOSE Frequently, three-dimensional (3D) conformal beams are used in lung cancer stereotactic body radiotherapy (SBRT). Recently, volumetric modulated arc therapy (VMAT) was introduced as a new treatment modality. VMAT techniques shorten delivery time, reducing the possibility of intrafraction target motion. However dose distributions can be quite different from standard 3D therapy. This stud...
متن کامل4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.
Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific ph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical radiation sciences
دوره 63 1 شماره
صفحات -
تاریخ انتشار 2016