Comparison of Intraocular Pressure Fluctuations Measured by Goldmann Applanation Tonometer and Pulsatile Ocular Blood Flow Analyser

نویسندگان

  • Ingrida Januleviciene
  • Loreta Kuzmiene
  • Ieva Sliesoraityte
چکیده

BACKGROUND Intraocular pressure (IOP) is the major known risk factor in glaucoma and the primer mover of the functional damage in glaucomatous patients but it is not a unique determinant of glaucomatous damage. Clinical assessment of glaucoma patients may not be a true reflection of overall IOP control. Evaluation of the effect of glaucoma medication is restricted by measurement of IOP as a dynamic physiological parameter. PURPOSE To compare IOP fluctuations over time using Goldmann applanation tonometry (IOPGAT) and pulsatile ocular blood flow analyzer (IOP-POBFA) under the Dorzolamide/timolol or latanoprost treatment regimes. DESIGN Prospective 1 year follow-up study. PARTICIPANTS 30 randomly chosen controlled open angle glaucoma patients (60 eyes): 16 patients (32 eyes) receiving Dorzolamide/timolol fixed combination (D/T) and 14 (28 eyes) latanoprost 0.005% treatment. MAIN OUTCOME MEASURES Changes in IOP and perfusion pressure dynamics. RESULTS THERE WAS NO STATISTICALLY SIGNIFICANT DIFFERENCE IN BASELINE IOP PARAMETERS BETWEEN STUDY GROUPS: 15.69 ± 2.02 mmHg with D/T and 16.71 ± 2.84 mmHg with latanoprost (p=0.314). Both treatment regimes were tolerated and patients were adherent to treatment. Determined a strong positive correlation between IOP-GAT and IOP-POBFA; verified over time period under particular treatment regime. After 1 year follow-up D/T and latanoprost results referred to statistically significant tachyphylaxis effect, i.e. IOP-GAT increased in 2.31mmHg with D/T (p=0.007) and 2.72 mmHg (p=0.004) with latanoprost and IOP-POBFA increased in 1.74 mmHg (p=0.026) and 3.13 mmHg (p=0.007) respectively. Multiple regression analysis revealed no important blood flow factors as predictors in the increase of IOP. CONCLUSIONS Strong positive correlation was revealed between IOP-POBFA and IOP-GAT over a time period. Observed tachyphylaxis effects after 1 year under both treatment regimes should be assessed with respect to patient compliance and persistence to treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Author’s response to reviews Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors:

Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors: Seung Pil Bang ([email protected]) Chong Eun Lee ([email protected]) Yu Cheol Kim ([email protected]) Version: 3 Date: 27 Jul 2017 Author’s response to reviews: Revision Letter Manuscript Number BOPH-D-17-00287 “Comparison of Int...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...