In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators.
نویسندگان
چکیده
AIMS To investigate the susceptibility of implantable cardioverter defibrillators to electromagnetic interference generated by digital cellular telephones, functioning in both international transmission technologies: the Global System for Mobile Communication (GSM) and the Digital Cellular System (DCS 1800). METHODS AND RESULTS In 36 patients with transvenous implantable cardioverter defibrillators from two manufacturers (Medtronic and Guidant/CPI), cellular telephones with different levels of minimal and maximal power output were tested in the transmitting and receiving mode. Evaluation was performed in activated implantable defibrillators during spontaneous cardiac activity and continuous VVI or DDD pacing to assess possible electromagnetic interference. In two patients, appropriateness of ventricular fibrillation detection and therapy was judged during telephone testing. There was no damage, reprogramming, inappropriate shock therapy or pacing inhibition during the tests. In seven pre-pectoral Medtronic implantable defibrillators, transient electromagnetic interference caused 19 erroneous sensing events, when the operating phone was held in close vicinity to the programmer head. These 'pseudo-oversensing' events, which did not result in logging of arrhythmia episodes in the device counter, were interpreted as an adverse interaction between the telephone and the programming device. CONCLUSION Digital cellular telephones do not represent a risk to Medtronic and Guidant/CPI recipients of the specific implantable defibrillator models herein tested.
منابع مشابه
Digital cellular telephone interaction with implantable cardioverter-defibrillators.
OBJECTIVES This study sought to determine, in vivo, whether electromagnetic interference (EMI), generated by North American Digital Communications (NADC)/Time Division Multiple Access-50-Hz (TDMA-50) mobile cellular digital telephone model AT&T 6650, disturbs normal implantable cardioverter-defibrillator (ICD) operation and to verify these observations in vitro by testing a selection of telepho...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملiPad2® Use in Patients With Implantable Cardioverter Defibrillators Causes Electromagnetic Interference: The EMIT Study
BACKGROUND Over 140 million iPads(®) have been sold worldwide. The iPad2(®), with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life-threatening situations in patients. The goal of this study was to determine whether the iPad2(®) can cause ...
متن کاملImplantable cardioverter defibrillator during laser transurethral resection of the prostate
Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...
متن کاملInterference Between Cellular Telephones and Implantable Rhythm Devices: A Review on Recent Papers
BACKGROUND Cardiac pacemakers and implantable defibrillators are potentially susceptible to electromagnetic interferences as they have complex circuitry for sensing and communication purposes. Cellular telephones being an important source of electromagnetic waves are likely to cause interference in the function of these devices. METHODS A systematic analysis of studies on interaction between ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 22 15 شماره
صفحات -
تاریخ انتشار 2001