Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system.

نویسندگان

  • Oluwatosin O Dada
  • Lauren M Ramsay
  • Jane A Dickerson
  • Nathan Cermak
  • Rong Jiang
  • Cuiru Zhu
  • Norman J Dovichi
چکیده

We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 +/- 120 yoctomoles for fluorescein in zone electrophoresis. Capillary isoelectric focusing of fluorescent standards produced peaks with an average width of 0.0029 +/- 0.0008 pH. Capillary coating stability limits the reproducibility of the analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary electrophoresis with wavelength-resolved laser-induced fluorescence detection.

Capillary electrophoresis (CE) enables rapid separations with high separation efficiency and compatibility with small sample volumes. Laser-induced fluorescence detection can result in extremely low limits of detection in CE. Single-channel fluorescence detection, however, furnishes little qualitative information about a species being detected, except for its CE migration time. Use of multidime...

متن کامل

Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...

متن کامل

Dynamic kinetic capillary isoelectric focusing: a powerful tool for studying protein-DNA interactions.

A new method called dynamic kinetic capillary isoelectric focusing (DK-CIEF) is presented for the study of protein-DNA interactions. The method is based on CIEF with laser-induced fluorescence-whole column imaging detection in which protein-DNA complexes are separated with spatial resolution while dissociations of the complexes are dynamically monitored using a CCD camera with temporal resoluti...

متن کامل

Micellar Electrokinetic Chromatography with Laser-Induced Fluorescence Detection for Separation of Red and Yellow Historical Dyes

In this study, the separation parameters in micellar electrokinetic chromatography (MEKC)-laser-induced fluorescence (LIF) were optimized for the separation of red and yellow historical dyes in 20 mM borate buffer with 20 mM sodium dodecyl sulfate (SDS). Separation conditions were optimized by changing pH, organic modifier (methanol and acetonitrile) concentrations and applied voltage. The mixt...

متن کامل

Whole-Column-Imaging Detection for Capillary Isoelectric Focusing and Capillary Electrophoresis

Despite the significant advantages of capillary isoelectric focusing over gel isoelectric focusing, widespread acceptance of the technique as a replacement for gel isoelectric focusing has not occurred. Several factors contribute to capillary isoelectric focusing’s slower-than-expected adoption; perhaps the most important are the performance and procedural difficulties introduced when capillary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 397 8  شماره 

صفحات  -

تاریخ انتشار 2010