Weekly versus daily changes of in-line suction catheters: impact on rates of ventilator-associated pneumonia and associated costs.

نویسندگان

  • James K Stoller
  • Douglas K Orens
  • Cynthia Fatica
  • Morgan Elliott
  • Lucy Kester
  • Jeff Woods
  • Lori Hoffman-Hogg Rn
  • Matthew T Karafa
  • Alejandro C Arroliga
چکیده

BACKGROUND An earlier randomized, controlled trial showed that weekly or as-needed (as opposed to daily) changes of in-line suction catheters were associated with substantial cost savings, without a higher rate of ventilator-associated pneumonia (VAP). To examine the impact of decreasing the frequency of in-line suction catheter changes in our medical intensive care unit, we conducted an observational study, comparing the catheter costs and frequency of VAP during (1) a control period, during which in-line suction catheters were changed daily, and (2) a treatment period, during which the catheters were changed every 7 days or sooner if needed, for mechanical failure or soilage. METHODS All adult patients admitted to our 18-bed medical intensive care unit were evaluated for the 3-month interval 1 year prior to the practice change (May through July 1998) and for the 3 months after implementing the new policy (May through July 1999). To avoid bias related to usual seasonal variation in VAP frequency, we also determined (via medical records) the VAP rate during May through July 1997. The occurrence of VAP was ascertained by an infection control practitioner, using criteria established by the Centers for Disease Control and applied in a standard fashion. The VAP rate was calculated as the mean number of VAPs per 100 ventilator-days for each 3-month interval. Use of ventilators, humidifiers, and non-heated-wire, disposable circuits was uniform during the study, as were policies regarding humidity, temperature settings, and frequency of routine ventilator circuit changes. RESULTS During the control period 146 patients accounted for 1,075 ventilator-days and there were 2 VAPs (0.19 VAPs per 100 ventilator-days). During the treatment period 143 patients accounted for 1,167 ventilator-days and there were no VAPs. The mean +/- SD duration of in-line suction catheter use during the treatment period was 3.8 +/- 0.8 days, and 51% of the patients had the same catheter in place for > 3 days (range 4-9 days). The actual cost of catheters used during the treatment period was lower than during the control period ($1,330 vs $6,026), predicting annual catheter cost savings of $18,782. CONCLUSIONS We conclude that (1) a policy of weekly (vs daily) change of in-line suction catheter is associated with substantial cost savings, with no significant increase in the frequency of VAP, and (2) to the extent that these findings confirm the results of prior studies they support a policy of changing in-line suction catheters weekly rather than daily.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical ventilation with or without daily changes of in-line suction catheters.

The purpose of this study was to determine the safety and cost-effectiveness of not routinely changing in-line suction catheters for patients requiring mechanical ventilation. Patients were randomly assigned to receive either no routine in-line suction catheter changes (n = 258) or in-line suction catheter changes every 24 h (n = 263). The main outcome measure was the incidence of ventilator-as...

متن کامل

Nurses’ knowledge of evidence- based guidelines for preventing ventilator-associated pneumonia in intensive care units

Background and Purpose: Implementing the guidelines to prevent VAP has been shown to have a significant effect on reducing the incidence of VAP. Studies indicate that ICU staff have poor knowledge and low implementation rate of the standard preventive measures related to VAP. The present study aims to evaluate the knowledge of nurses in the intensive care unit in University hospitals of Sari. ...

متن کامل

Evaluation of the Effects of Oronasal Versus Oral Disinfections with Chlorhexidine on Clinical Criteria of Ventilator-associated Pneumonia

Background: Ventilator-associated pneumonia (VAP) is the most prevalent and lethal form of nosocomial infections in the ICU and oral disinfection is a nursing measure to prevent this condition. Aim: this study aimed to evaluate the effect of oronasal versus oral disinfections with chlorhexidine on the clinical criteria for diagnosis of VAP. Method: This randomized clinical trial was conducted o...

متن کامل

AARC Evidence-Based Clinical Practice Guidelines Care of the Ventilator Circuit and Its Relation to Ventilator-Associated Pneumonia

of Recommendations • Ventilator circuits should not be changed routinely for infection control purposes. The maximum duration of time that circuits can be used safely is unknown. • Evidence is lacking related to ventilator-associated pneumonia (VAP) and issues of heated versus unheated circuits, type of heated humidifier, method for filling the humidifier, and technique for clearing condensate ...

متن کامل

Care of the ventilator circuit and its relation to ventilator-associated pneumonia.

Ventilator circuits should not be changed routinely for infection control purposes. The maximum duration of time that circuits can be used safely is unknown. Evidence is lacking related to ventilator-associated pneumonia (VAP) and issues of heated versus unheated circuits, type of heated humidifier, method for filling the humidifier, and technique for clearing condensate from the ventilator cir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2003