Free-breathing myocardial T2* mapping using GRE-EPI and automatic Non-rigid motion correction
نویسندگان
چکیده
BACKGROUND Measurement of myocardial T2* is becoming widely used in the assessment of patients at risk for cardiac iron overload. The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo (MGRE) sequence used for myocardial T2* quantification is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. We propose a free-breathing myocardial T2* mapping approach that combines a single-shot gradient-echo echo-planar imaging (GRE-EPI) sequence for T2*-weighted image acquisition with automatic non-rigid motion correction (MOCO) of respiratory motion between single-shot images. METHODS ECG-triggered T2*-weighted images at different echo times were acquired by a black-blood, single-shot GRE-EPI sequence during free-breathing. A single image at a single TE is acquired in each heartbeat. Automatic non-rigid MOCO was applied to correct for in-plane respiratory motion before pixel-wise T2* mapping. In a total of 117 patients referred for clinical cardiac magnetic resonance exams, the free-breathing MOCO GRE-EPI sequence was compared to the breath-hold segmented MGRE approach. Image quality was scored independently by 2 experienced observers blinded to the particular image acquisition strategy. T2* measurements in the interventricular septum and in the liver were compared for the two methods in all cases with adequate image quality. RESULTS T2* maps were acquired in all 117 patients using the breath-hold MGRE and the free-breathing MOCO GRE-EPI approaches, including 8 patients with myocardial iron overload and 25 patients with hepatic iron overload. The mean image quality of the free-breathing MOCO GRE-EPI images was scored significantly higher than that of the breath-hold MGRE images by both reviewers. Out of the 117 studies, 21 breath-hold MGRE studies (17.9% of all the patients) were scored to be less than adequate or very poor by both reviewers, while only 2 free-breathing MOCO GRE-EPI studies were scored to be less than adequate image quality. In a comparative evaluation of the images with at least adequate quality, the intra-class correlation coefficients for myocardial and liver T2* were 0.868 and 0.986 respectively (p < 0.001), indicating that the T2* measured by breath-hold MGRE and free-breathing MOCO GRE-EPI were in close agreement. The coefficient of variation between the breath-hold and free-breathing approaches for myocardial and liver T2* were 9.88% and 9.38% respectively. Bland-Altman plots demonstrated good absolute agreement of T2* in the interventricular septum and the liver from the free-breathing and breath-hold approaches (mean differences -0.03 and 0.16 ms, respectively). CONCLUSION The free-breathing approach described for T2* mapping using MOCO GRE-EPI enables accurate myocardial and liver T2* measurements and is insensitive to respiratory motion.
منابع مشابه
Free-breathing myocardial T2* mapping using GRE-EPI and MOCO for myocardial and hepatic iron overload assessment: a multi-centre study
Background T2* measurement is widely used in the assessment of patients at risk for cardiac and hepatic iron overload (1,2). The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo sequence (BH MGRE) used for myocardial T2* quantification (3) is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. To overcome this limit...
متن کاملMyocardial T1 and T2 mappings with automatic motion correction at 3 Tesla MR: comparison of T1 and T2 measurements by breathhold, free-breathing and cardiac cycle
Methods Myocardial T1 and T2 mapping at 3 Tesla MR was obtained from 24 healthy volunteers (16 males and 8 females, mean age, 31±4 years). Shortened modified looklocker inversion recovery was used for T1 mapping and T2-prepared single-shot steady-state free precession was utilized for T2 mapping. Automatic motion correction was done by an elastic registration algorithm based on estimating motio...
متن کاملMotion correction for free breathing quantitative myocardial t2 mapping: impact on reproducibility and spatial variability
Background Quantitative myocardial T2 mapping is a promising technique for in-vivo assessment of inflammation and edema [1]. Free breathing T2 mapping sequences increase the flexibility in the choice of the number of T2prep echoes times (TET2P), but should be combined with respiratory motion correction technique [2]. In this study, we sought to evaluate the performance of the Adaptive Registrat...
متن کاملImproved T2-Weighted Cardiac Imaging using Retrospective Motion Correction and Optimal Image Combination
Introduction T2-weighted (T2w) cardiac MR imaging has established reputation as a sensitive technique to depict myocardial edema related to acute infarction. Together with delayed enhancement technique, T2w demonstrated valuable clinical potentials to differentiate acute damage from chronic infarction [1]. To minimize the myocardial signal loss caused by through-plane motion, T2w can be perform...
متن کاملNon-rigid registration and KLT filter to improve SNR and CNR in GRE-EPI myocardial perfusion imaging.
The purpose of the study was to evaluate the effect of motion compensation by non-rigid registration combined with the Karhunen-Loeve Transform (KLT) filter on the signal to noise (SNR) and contrast-to-noise ratio (CNR) of hybrid gradient-echo echoplanar (GRE-EPI) first-pass myocardial perfusion imaging. Twenty one consecutive first-pass adenosine stress perfusion MR data sets interpreted posit...