Evaluation of fluorescence polarization immunoassay for serum thyroxine determination.

نویسندگان

  • M Muratsugu
  • M Makino
چکیده

We have evaluated a fluorescence polarization immunoassay for thyroxine (T4) using the polarization analyzer IBF-129. Fluorescence polarization could be measured within 20 to 23 seconds after addition of fluorescein labeled thyroxine. The method exhibited excellent specificity and acceptable accuracy. The average intra- and inter-assay coefficients of variation were 4.8 and 12.3%, resepectively. The fluorescence polarization immunoassay was compared with a radioimmunoassay (RIA) using 96 clinical serum samples and gave a linear regression equation: y = 0.92 x + 12.5, with a correlation coefficient of r = 0.866 (P less than 0.001).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an automated fluorescence polarization immunoassay for vancomycin.

An automated fluorescence polarization immunoassay for the determination of vancomycin levels in serum was evaluated. The vancomycin assay is a homogeneous competitive inhibition immunoassay based on changes in fluorescence polarization that occur with antibody binding. This assay was compared with a liquid chromatographic assay and an agar well diffusion bioassay method by using clinical serum...

متن کامل

Endogenous antibodies that interfere with thyroxine fluorescence polarization assay but not with radioimmunoassay or EMIT.

We have identified an individual whose thyroxine (T4) concentration was undetectable with Abbott's fluorescence polarization immunoassay (FPIA) but within the reference range by radioimmunoassay or EMIT (Syva). The patient's thyrotropin, triiodothyronine, and T-uptake values were within the normal range. The T4 concentration measured by FPIA increased to normal when the immunoglobulin fraction ...

متن کامل

Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.

We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...

متن کامل

Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.

Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immuno...

متن کامل

Evaluation of the manual enzyme immunoassay (EMIT) procedure for determination of serum thyroxine.

Our experience with the determination of thyroxine (T4) in serum using a homogeneous enzyme immunoassay technique (EMIT, Syva Corp.) is reported. The intra-assay precision of the EMIT Manual Thyroxine Assay was investigated with 2 different calibrator concentrations and showed coefficients of variation varying from 5--2% for thyroxine concentrations of 40 and 120 micrograms/l thyroxine respecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 20 8  شماره 

صفحات  -

تاریخ انتشار 1982