The bone diagnostic instrument III: testing mouse femora.
نویسندگان
چکیده
Here we describe modifications that allow the bone diagnostic instrument (BDI) [P. Hansma et al., Rev. Sci. Instrum. 79, 064303 (2008); Rev. Sci. Instrum. 77, 075105 (2006)], developed to test human bone, to test the femora of mice. These modifications include reducing the effective weight of the instrument on the bone, designing and fabricating new probe assemblies to minimize damage to the small bone, developing new testing protocols that involve smaller testing forces, and fabricating a jig for securing the smaller bones for testing. With these modifications, the BDI was used to test the hypothesis that short-term running has greater benefit on the mechanical properties of the femur for young growing mice compared to older, skeletally mature mice. We measured elastic modulus, hardness, and indentation distance increase (IDI), which had previously been shown to be the best discriminators in model systems known to exhibit differences in mechanical properties at the whole bone level. In the young exercised murine femora, the IDI was significantly lower than in young control femora. Since IDI has a relation to postyield properties, these results suggest that exercise during bone development increases post yield mechanical competence. We were also able to measure effects of aging on bone properties with the BDI. There was a significant increase in the IDI, and a significant decrease in the elastic modulus and hardness between the young and old groups. Thus, with the modifications described here, the BDI can take measurements on mouse bones and obtain statistically significant results.
منابع مشابه
The genetic influence on bone susceptibility to fluoride.
INTRODUCTION The influence of genetic background on bone architecture and mechanical properties is well established. Nevertheless, to date, only few animal studies explore an underlying genetic basis for extrinsic factors effect such as fluoride effect on bone metabolism. MATERIALS AND METHODS This study assessed the effect of increasing fluoride doses (0 ppm, 25 ppm, 50 ppm, 100 ppm) on the ...
متن کاملEmbalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?
BACKGROUND AND PURPOSE The most frequently used bones for mechanical testing of orthopedic and trauma devices are fresh frozen cadaveric bones, embalmed cadaveric bones, and artificial composite bones. Even today, the comparability of these different bone types has not been established. METHODS We tested fresh frozen and embalmed cadaveric femora that were similar concerning age, sex, bone mi...
متن کامل0552 - in Vitro Sodium Fluoride Exposure Decreases Strength and Increases Ductility of Mouse Femora
Introduction: Fluoride has been advocated for the treatment of osteoporosis because of its anabolic effect on osteoblasts. Fluoride can also alter bone mineral structure, and several investigators have inferred that the alteration in bone mineral causes a reduction in bone tissue strength that can negate the positive effects of increased formation [1-3]. However, the direct effects of fluoride-...
متن کاملP - 5 Effects of Bipedal Loading during Lactation and Post - Lactation Recovery on Femoral Bone Strength in Rats
The use of computed microtomography (ÌCT) for imaging and quantitating skeletal architecture in mice is quickly becoming a standard laboratory tool. The current maximum spatial resolution of commercially available imaging systems is approximately 10 Ìm, while the thickness and spacing of trabeculae in mouse bone typically range from 70 Ìm down to 20 Ìm and smaller. Meaningful quantitation of mo...
متن کاملEffect of three different sanitizing solutions on the contaminated bone: an experimental study in the rabbit
Background: To determine the efficacy of three different antiseptic solutions (Control group (I), Antibiotic solution – Neomycin and polymyxin (II), Chlorhexidine 0.4% (III), and povidone – iodine 10% (IV)) in disinfecting contaminated bone fragments. Methods: Under sterile conditions, the femora of 12 rabbits were removed and cut into six millimeter pieces. A total of 200 bone specimens were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 80 6 شماره
صفحات -
تاریخ انتشار 2009