A new scoring system derived from base excess and platelet count at presentation predicts mortality in paediatric meningococcal sepsis

نویسندگان

  • Alexessander Couto-Alves
  • Victoria J Wright
  • Karnan Perumal
  • Alexander Binder
  • Enitan D Carrol
  • Marieke Emonts
  • Ronald de Groot
  • Jan Hazelzet
  • Taco Kuijpers
  • Simon Nadel
  • Werner Zenz
  • Padmanabhan Ramnarayan
  • Michael Levin
  • Lachlan Coin
  • David P Inwald
چکیده

INTRODUCTION The aim of this study was to derive a novel prognostic score for mortality in paediatric meningococcal sepsis (MS) based on readily available laboratory markers. METHODS A multicentre retrospective cohort study for the consortium set and a single centre retrospective study for replication set. The consortium set were 1,073 children (age 1 week to 17.9 years) referred over a 15-year period (1996 to 2011), who had an admission diagnosis of MS, referred to paediatric intensive care units (PICUs) in six different European centres. The consortium set was split into a development set and validation set to derive the score. The replication set were 134 children with MS (age 2 weeks to 16 years) referred over a 4-year period (2007 to 2011) to PICUs via the Children's Acute Transport Service (CATS), London. RESULTS A total of 85/1,073 (7.9%) children in the consortium set died. A total of 16/134 (11.9%) children in the replication set died. Children dying in the consortium set had significantly lower base excess, C-reactive protein (CRP), platelet and white cell count, more deranged coagulation and higher lactate than survivors. Paediatric risk of mortality (PRISM) score, Glasgow meningococcal septicaemia prognosis score (GMSPS) and Rotterdam score were also higher. Using the consortium set, a new scoring system using base excess and platelet count at presentation, termed the BEP score, was mathematically developed and validated. BEP predicted mortality with high sensitivity and specificity scores (area under the curve (AUC) in the validation set=0.86 and in the replication set=0.96). In the validation set, BEP score performance (AUC=0.86, confidence interval (CI): 0.80 to 0.91) was better than GMSPS (AUC=0.77, CI: 0.68, 0.85), similar to Rotterdam (AUC=0.87, CI: 0.81 to 0.93) and not as good as PRISM (AUC=0.93, CI: 0.85 to 0.97). CONCLUSIONS The BEP score, relying on only two variables that are quickly and objectively measurable and readily available at presentation, is highly sensitive and specific in predicting death from MS in childhood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Invasive Meningococcal Disease: Application of Base Excess and Platelets Score in a Portuguese Paediatric Intensive Care Unit Doença Meningocócica Invasiva: Aplicação do Base Excess and Platelets Score numa Unidade de Cuidados Intensivos Pediátricos Portuguesa

342 Revista Científica da Ordem dos Médicos www.actamedicaportuguesa.com ABSTRACT Introduction: Meningococcal infection has a high mortality and morbidity. Recently a new prognostic scoring system was developed for paediatric invasive meningococcal disease, based on platelet count and base excess – base excess and platelets score. The main objective of this study was to evaluate the accuracy of...

متن کامل

The Prognostic Role of Mean Platelet Volume (MPV) in Sever Sepsis: is it True?

Background: The purpose of the present study was to examine the role of mean platelet volume (MPV) in comparison with Sequential Organ Failure Assessment (SOFA), quick SOFA (qSOFA), and Mortality in Severe Sepsis in the Emergency Department (MISSED) scoring systems in predicting hospital mortality among patients with severe sepsis. Methods: This follow-up stud...

متن کامل

A simple meningococcal sepsis prognostic score: focusing on the human animal

A simple cheap meningococcal sepsis prognostic score based on readily available, rapid, objective laboratory base excess and platelet count was developed and validated retrospectively. This BEP score should facilitate sepsis clinical trials, allowing study of the relevant human animal model.

متن کامل

The Evaluation of Mean Platelet Volume in Neonates with Intraventricular Hemorrhage and Sepsis

Background: Neonatal sepsis is a generalized bacterial infection which occurs in the first month of life. Intraventricular hemorrhage is the most common intracerebral disorder which occurs in premature neonates. Mean Platelet Volume (MPV) is considered as a marker of intraventricular hemorrhage (IVH) in some studies. The aim of this study was to evaluate the impact of MPV on IVH and sepsis in n...

متن کامل

Diagnostic Evaluation of Hematological Sepsis Score and Presepsin in Neonatal Sepsis

Background: Early detection of neonatal sepsis and categorization of patients based on clinical severity is not yet effectively achieved. Some hematological parameters are used to formulate a hematological scoring system (HSS) and a modified hematological scoring system (MHSS) to diagnose neonatal sepsis. A promising biomarker: Presepsin, or Soluble Cluster of Differentiation 14 SubType (sCD14-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2013