SU-E-T-584: Dosimetric Comparison Between Static IMRT and VMAT for a Four- Lesion Brain Treatment.

نویسندگان

  • Y Lo
  • R Sheu
  • I Germano
  • S Green
چکیده

PURPOSE Sparing brain volume is the goal when designing plans for multiple brain tumors. We compared dose distributions for tumor and normal tissues using VAMT and static IMRT. METHODS A patient presented with recurrent meningioma with 4 lesions identified. The greatest dimensions for the tumors were 0.4 to 2.0 cm. The tumor sizes and locations can be treated with a single plan with 1.8 Gy/fraction, 30 fractions. A 6-field non-coplanar IMRT with the gantry(G) and couch(C) in IEC scale were used: G0C0, G45C0, G330C0, G240C0, G50C90, and G120C90. IMRT was performed using iPlan sliding-window. For VMAT, four arcs were used; two using 350 degree from G175 to G185 and the other two using 175 degree from G0 to G175. Two arcs were designed with couch=0 and the rest two using couch=90 degree. VMAT was designed with Eclipse system. Tumors and normal brain were contoured in the iPlan and then exported to Eclipse to maintain identical volume. DVH for normal brain was compared for the same tumor coverage from the two plans. RESULTS Either static IMRT or VMAT generated an acceptable coverage for these four tumors. The conformity of tumor coverage was better in VMAT than that using IMRT; the range of min.-max. doses were: 57.5-63.5 Gy from VMAT vs. 54.1-64.9 Gy from IMRT. For normal brain, DVH did not show a clear difference between the two plans. For doses 5-15 Gy, VMAT delivered 1- 10% more brain volume (1040 cc) but 1-2 % less volume in 30-40 Gy than that from static IMRT. CONCLUSIONS Either static IMRT or VMAT can adequately be used to treat multiple lesions with a single isocenteric treatment. VMAT plan demonstrated improved tumor coverage, spared 1- 2% brain tissue at 30-40 Gy but irradiated up to 10% more brain in 2-7 Gy. The patient was treated with VMAT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-T-593: VMAT Vs. IMRT for Treatment of Neoplasms of the Brain: Dosimetric Quality and Delivery.

PURPOSE A retrospective study was performed to determine any dosimetric or delivery benefits for treatment planning with intensity-modulated radiotherapy (IMRT) versus volumetric-modulated arc therapy (VMAT) for the treatment of brain neoplasms. METHODS Eighteen patients treated with modulated brain radiotherapy treatments were included in this study (primary treatment volumes of 15.3 to 374....

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.

PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...

متن کامل

A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

BACKGROUND To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). METHODS Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part19  شماره 

صفحات  -

تاریخ انتشار 2012