The use of a portable breath analysis device in monitoring type 1 diabetes patients in a hypoglycaemic clamp: validation with SIFT-MS data.

نویسندگان

  • C Walton
  • M Patel
  • D Pitts
  • P Knight
  • S Hoashi
  • M Evans
  • C Turner
چکیده

Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor the blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor during hypoglycaemic glucose clamps and compare that with the use of SIFT-MS described in previously published work on the same set of patients. Outputs from both devices have been correlated with the concentration of blood glucose in eight volunteers suffering from type 1 diabetes mellitus. The results demonstrate that acetone as measured by SIFT-MS and the sensor output from the breath sensing device both correlate linearly with blood glucose; however, the sensor response and acetone concentrations differ greatly between patients with the same blood glucose. It is therefore unlikely that breath analysis can entirely replace blood glucose testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of a portable breath analysis device in monitoring diabetes patients in a hypoglycaemic clamp: Validation with SIFT-MS data

Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor du...

متن کامل

Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps Running head: Breath acetone in type 1 diabetes

Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry (SIFT-MS) to monitor the breath of 8 patients with type...

متن کامل

Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps.

Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry to monitor the breath of eight patients with type 1 dia...

متن کامل

Design and Validation of an Assessment Tool to Determine the Level of Self-Care of Patients Affected by Diabetes Type II

Background and Aim: Diabetes Type II is a chronic metabolic disorder rising its prevalence worldwide. Self-care is the most important management strategy to control the disorder and its adverse effects. The aim of this study was to design and validate an assessment tool to determine the level of self-care of patients affected by Diabetes type II. Materials and Methods: This study was a cross-s...

متن کامل

Validation of the analysis method of 25 pesticide residues in rice using LC-MS/MS device (liquid chromatography-mass spectrometry)

Introduction: In recent years, due to the increase in the use of pesticides in agricultural products and its entry into the human food chain, there has been an increase in concerns about the health of food among people. Therefore, the purpose of conducting this research is to validate the analysis method. 25 pesticide residues in rice using LC-MS/MS. Methods: In this research, a simultaneous an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of breath research

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2014