Predictive factors for pacemaker requirement after transcatheter aortic valve implantation
نویسندگان
چکیده
BACKGROUND Transcatheter aortic valve implantation (TAVI) has been established as a treatment option for inoperable patients with symptomatic aortic valve stenosis. However, patients suffer frequently from conduction disturbances after TAVI. METHODS Baseline, procedural as well as surface and intracardiac ECG parameters were evaluated for patients treated with TAVI and a comparison between patients requiring pacemaker with those not suffering from relevant conduction disorders were done. RESULTS TAVI was successfully in all patients (n=45). Baseline surface and intracardiac ECG recording revealed longer PQ (197.1±51.2 msec versus 154.1±32.1 msec; p<0.001), longer AH (153.6±43.4 msec versus 116.1±31.2 msec; p<0.001) and HV interval (81.7±17.8 msec versus 56.8±8.5 msec; p<0.001) in patients with need for a pacemaker (n=23) versus control group (n=22); furthermore, 7-day follow-up analysis showed a higher prevalence of new left bundle branch block (LBBB) (87.0% versus 31.9%; p<0.001). Multivariate analysis revealed that only new LBBB, QRS duration >120 msec and a PQ interval >200 msec immediately (within 60 minutes) after implantation of the aortic valve were predictors for high-grade (type II second-degree and third-degree) AV block. Other clinical parameters as well as baseline electrocardiographic parameters had no impact on critical conduction delay. CONCLUSION Cardiac conduction disturbances are common after TAVI. The need for pacing after TAVI is predictable by surface ECG evaluation immediately (within 60 minutes) after the procedure.
منابع مشابه
Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
OBJECTIVES The aim of this study was to compare the incidence and predictive factors of complete atrioventricular block (AVB) and permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) versus surgical aortic valve replacement (SAVR). BACKGROUND No data exist on the need for PPI after TAVI versus SAVR in patients with similar baseline electrocardiographic (...
متن کاملA Case of Transient Advanced Atrioventricular Block after Aortic Valve Replacement, Report of a Case
Approximately 3% 11.8% of cases require permanent pacemaker implantation due to atrioventricular block (AVB) after aortic valve replacement (AVR), and determination of conduction disturbances such as left or right bundle branch block by preoperative electrocardiography is correlated with high risk postoperative permanent pacemaker implantation. Intraoperative risk factors include severe calcifi...
متن کاملConduction disorders and transcatheter aortic valve. Clinically relevant or just a mild complication?
Ten years after the introduction of transcatheter aortic valve implantation (TAVI), an estimated 90 000 or more of these procedures have been performed around the world. This explosive growth of a new treatment can be explained by several factors: a) the large number of patients who are candidates for this approach, since aortic stenosis (AS) is the most common valve disease in adults and its i...
متن کاملThe Conundrum of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation.
Transcatheter aortic valve implantation (TAVI) has matured into the preferred treatment modality for patients with severe aortic stenosis at extreme or high risk for conventional surgery and a valuable alternative for those at intermediate risk in view of similar or superior clinical outcomes and decreased rates of periprocedural adverse events. In this context, it remains unclear whether other...
متن کاملFactors predicting and having an impact on the need for a permanent pacemaker after CoreValve prosthesis implantation using the new Accutrak delivery catheter system.
OBJECTIVES The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) using the new Accutrak delivery system (Medtronic, Inc.). BACKGROUND The need for a permanent pacemaker is a recognized complication after transcatheter aortic valve implantation with the C...