Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.
نویسندگان
چکیده
BACKGROUND Ultrasound can cause microbubble destruction. If microbubbles are administered as a continuous infusion, then their destruction within the myocardium and measurement of their myocardial reappearance rate at steady state will provide a measure of mean myocardial microbubble velocity. Conversely, measurement of their myocardial concentration at steady state will provide an assessment of microvascular cross-sectional area. Myocardial blood flow (MBF) can then be calculated from the product of the two. METHODS AND RESULTS Ex vivo and in vitro experiments were performed in which either flow was held constant and pulsing interval (interval between microbubble destruction and replenishment) was altered, or vice versa. In vivo experiments were performed in 21 dogs. In group 1 dogs (n=7), MBF was mechanically altered in a model in which coronary blood volume was constant. In group 2 dogs (n=5), MBF was altered by direct coronary infusions of vasodilators. In group 3 dogs (n=9), non-flow-limiting coronary stenoses were created, and MBF was measured before and after the venous administration of a coronary vasodilator. In all experiments, microbubbles were delivered as a constant infusion, and myocardial contrast echocardiography was performed using different pulsing intervals. The myocardial video intensity versus pulsing interval plots were fitted to an exponential function: y=A(1-e[-betat]), where A is the plateau video intensity reflecting the microvascular cross-sectional area, and beta reflects the rate of rise of video intensity and, hence, microbubble velocity. Excellent correlations were found between flow and beta, as well as flow and the product of A and beta. CONCLUSIONS MBF can be quantified with myocardial contrast echocardiography during a venous infusion of microbubbles. This novel approach has potential for measuring tissue perfusion in any organ accessible to ultrasound.
منابع مشابه
Quantification of Myocardial Blood Flow Using Microbubbles
Ultrasound can cause microbubble destruction. We hypothesized that ultrasound induced microbubble destruction can be used to quantify myocardial blood flow. in viva experiments were performed where microbubbles were delivered as a constant infusion, and ultrasound examination was performed using different pulsing intervals from which microbubble velocity and microvascular cross-sectional area w...
متن کاملBasis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
OBJECTIVES This study sought to determine the basis of detection of stenosis by myocardial contrast echocardiography using venous administration of microbubbles and to define the relative merits of bolus injection versus continuous infusion. BACKGROUND The degree of video intensity (VI) disparity in myocardial beds supplied by stenosed and normal coronary arteries can be used to quantify sten...
متن کاملAssessment of transmural distribution of myocardial perfusion with contrast echocardiography.
BACKGROUND We hypothesized that by using our newly defined method of destroying microbubbles and measuring their rate of tissue replenishment, we could assess the transmural distribution of myocardial perfusion. METHODS AND RESULTS We studied 12 dogs before and after creation of left anterior descending coronary artery stenoses both at rest and during hyperemia (n=62 stages). Microbubbles wer...
متن کاملReal-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound.
Current methods for measuring renal blood flow (RBF) are time consuming and not widely available. Contrast-enhanced ultrasound (CEU) is a safe and noninvasive imaging technique suitable for assessment of tissue blood flow, which has been used clinically to assess myocardial blood flow. We tested the utility of CEU in monitoring changes in RBF in healthy volunteers. We utilized CEU to monitor th...
متن کاملBlood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects
Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...