Transport and accumulation of ferrocene tagged poly(vinyl chloride) at the buried interfaces of plasticized membrane electrodes.

نویسندگان

  • Manzar Sohail
  • Roland De Marco
  • Muhammad Tanzirul Alam
  • Marcin Pawlak
  • Eric Bakker
چکیده

Cyclic voltammetry (CV), synchrotron radiation-X-ray photoelectron spectroscopy (SR-XPS) and near edge X-ray absorption fine structure (NEXAFS) show that oxidation of ferrocene tagged PVC induces an accumulation of high molecular weight polymer at the buried interface between the substrate electrode and the plasticized membrane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsed chronopotentiometric membrane electrodes based on plasticized poly(vinyl chloride) with covalently bound ferrocene functionalities as solid contact transducer*

Ion-selective membrane materials based on poly(vinyl chloride) (PVC)-containing covalently attached redox-active ferrocene (Fc) groups are characterized here as all-solidstate pulsed voltammetric ion sensors. The redox capacity of the membrane increases 7-fold with a doubling of the Fc content and 3-fold with the addition of 10 wt % of the lipophilic electrolyte ETH 500, tetradodecylammonium te...

متن کامل

The Plasticizing Mechanism and Effect of Aluminium Chloride and Glycerin on Poly(vinyl alcohol) Films

Poly(Vinyl Alcohol) (PVA) films were prepared with AlCl3·6H2O/glycerin and AlCl3·6H2O/poly glycerin as two kinds of complex plasticizer. The micromorphology of pure PVA film and PVA films plasticized with complex plasticizer was observed by Scanning Electron Microscope (SEM). The interaction between complex plas...

متن کامل

Comparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques

Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

متن کامل

Flow-Injection Coulometric Detection Based on Ion Transfer and Its Application to the Determination of Chlorpromazine

A flow-injection coulometric method for the determination of chlorpromazine based on ion transfer into a plasticized poly(vinyl chloride) (PVC) membrane, was developed. The detector used consists of a flow-through cell that incorporates a plasticized poly(vinyl chloride) (PVC) membrane which contains tetrabutylammonium tetraphenylborate as electrolyte. The membrane is located between the flowin...

متن کامل

Flow-Injection Amperometric Determination of Tacrine based on Ion Transfer across a Water–Plasticized Polymeric Membrane Interface

A flow-injection pulse amperometric method for determining tacrine, based on ion transfer across a plasticized poly(vinyl chloride) (PVC) membrane, was developed. A four-electrode potentiostat with ohmic drop compensation was used, while a flow-through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. The influence of the applied poten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 138 15  شماره 

صفحات  -

تاریخ انتشار 2013