Model-based insulin sensitivity as a sepsis diagnostic in critical care.

نویسندگان

  • Amy Blakemore
  • Sheng-Hui Wang
  • Aaron Le Compte
  • Geoffrey M Shaw
  • Xing-Wei Wong
  • Jessica Lin
  • Thomas Lotz
  • Christopher E Hann
  • J Geoffrey Chase
چکیده

BACKGROUND Timely diagnosis and treatment of sepsis in critical care require significant clinical effort, experience, and resources. Insulin sensitivity is known to decrease with worsening condition and could thus be used to aid diagnosis. Some glycemic control protocols are able to identify insulin sensitivity in real time. METHODS Receiver operating characteristic curves and cutoff insulin sensitivity values for diagnosing sepsis were calculated for model-based insulin sensitivity (S(I)) and a simpler metric (SS(I)) that was estimated from glycemic control data of 30 patients with sepsis and can be calculated in real time without use of a computer. Results were compared to the insulin sensitivity profiles of a general intensive care unit population of 113 patients without sepsis and 30 patients with sepsis, comprising a total of 26,453 patient hours. Patients with sepsis were identified as having sepsis based on a sepsis score (ss) of 3 or higher (ss = 0 - 4 for increasing severity). Patients with type I or type II diabetes were excluded. Ethics approval for this study was granted by the South Island Regional Ethics Committee. RESULTS Receiver operating characteristic cutoff values of S(I) = 8 x 10-5 liter mU(-1) min(-1) and SS(I) = 2.8 x 10-4 liter mU(-1) min(-1) were determined for ss > or = 3. The model-based S(I) fell below this value in 15% of all patient hours. The S(I) test had a negative predictive value of 99.8%. The test sensitivity was 78% and specificity was 82%. However, the positive predictor value was 2.8%. Slightly lower sensitivity (68.8%) and specificity (81.7%), but equally good negative prediction (99.7%), were obtained for the estimated SS(I). CONCLUSIONS Insulin sensitivity provides a negative predictive diagnostic for sepsis. High insulin sensitivity rules out sepsis for the majority of patient hours and may be determined noninvasively in real time from glycemic control protocol data. Low insulin sensitivity is not an effective diagnostic, as it can equally mark the presence of sepsis or other conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a model-based clinical sepsis biomarker for critically ill patients

Sepsis occurs frequently in the intensive care unit (ICU) and is a leading cause of admission, mortality, and cost. Treatment guidelines recommend early intervention, however positive blood culture results may take up to 48 h. Insulin sensitivity (S(I)) is known to decrease with worsening condition and could thus be used to aid diagnosis. Some glycemic control protocols are able to accurately i...

متن کامل

Diagnostic Evaluation of Hematological Sepsis Score and Presepsin in Neonatal Sepsis

Background: Early detection of neonatal sepsis and categorization of patients based on clinical severity is not yet effectively achieved. Some hematological parameters are used to formulate a hematological scoring system (HSS) and a modified hematological scoring system (MHSS) to diagnose neonatal sepsis. A promising biomarker: Presepsin, or Soluble Cluster of Differentiation 14 SubType (sCD14-...

متن کامل

Eosinopenia and Neutrophil to lymphocyte ratio as diagnostic tools in neonatal early onset sepsis -a single center observational study

Background and Objective: Neonatal sepsis is associated with high mortality and has a favourable outcome when recognized and treated in a timely manner. In resource-limited settings, there is a need for an affordable test with a short turnaround time for timely diagnosis of sepsis. The aim of this study was to find out the role of eosinopenia and neutrophil-to-lymphocyte ratio (NLR) in screenin...

متن کامل

Diagnostic Role of Serum Haptoglobin level in Early Onset Neonatal Sepsis

Background: Introduction: Searching for an ideal marker for diagnosing neonatal infection is still an important concern in every country. There are many biomarkers reported for neonatal sepsis. Haptoglobin is an acute phase reactants which rise in response to infection and injuries. In this report we discussed the efficacy of serum haptoglobin level in different cut off levels in early onset ne...

متن کامل

Sensitivity And Specificity Of Procalcitonin In Diagnosis Of Neonatal Sepsis

  Background and Objective: According to the fact that neonatal infection is a challenging diagnosis field, several studies have tried to test sensitivity and specificity of diagnostic tests. This study was conducted to evaluate the sensitivity and specificity of procalcitonin (PCT) as a single early marker of neonatal sepsis. Materials and Methods: In this study, 150 neonates admitted to NIC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2008