Contouring the middle and inner ear on radiotherapy planning scans.

نویسندگان

  • Heather D Pacholke
  • Robert J Amdur
  • Ilona M Schmalfuss
  • Debbie Louis
  • William M Mendenhall
چکیده

The purpose of this study was to establish guidelines that help radiation oncologists contour the inner and middle ear on treatment planning scans. The radiotherapy computed tomography (CT) scans of 15 previously treated patients were reviewed for the ability to identify 3 separate auditory structures. The middle ear, the cochlea, and the vestibular apparatus were identified and contoured on each scan using anatomic landmarks. The volume and maximum axial dimension of each contour were calculated. The middle ear, cochlea, and vestibular apparatus were identified on all scans. The middle ear was defined by the tympanic membrane laterally and by the interface between air and the temporal bone in all other directions. The plane of the internal auditory canal through the temporal bone was the landmark distinguishing the vestibular apparatus from the cochlea. The mean volume of the middle ear, vestibular apparatus, and cochlea were 0.58 cm3, 0.44 cm3, and 0.14 cm3, respectively. The maximum axial dimension across the contour averaged 1.57 cm for the middle ear, 1.10 cm for the vestibular apparatus, and 0.69 cm for the cochlea. A reference atlas was constructed that shows the contour of each structure on 5 consecutive CT images. Accurate identification of the middle ear and inner ear structures on radiotherapy planning scans is possible and is necessary if critical auditory organs are to be spared during radiotherapy of targets that are located near the base of the skull. The information generated in this study will help radiation oncologists contour auditory structures accurately.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of replacing cochlea contour with inner ear contour on cochlea dose-volume calculations in conventional 2 dimensional and conformal 3 dimensional radiotherapy of brain

Introduction: Sensorineural hearing loss (SNHL) is one of the possible complications of radiotherapy treatment of brain tumors. The auditory system of patients with brain tumors often is placed inside of radiation field and receives a significant amount of radiation dose resulting in hearing loss. The purpose of this study was to compare contouring and delivery dose to cochlea...

متن کامل

Recommendation for a contouring method and atlas of organs at risk in nasopharyngeal carcinoma patients receiving intensity-modulated radiotherapy.

BACKGROUND AND PURPOSE To recommend contouring methods and atlas of organs at risk (OARs) for nasopharyngeal carcinoma (NPC) patients receiving intensity-modulated radiotherapy, in order to help reach a consensus on interpretations of OARs delineation. METHODS AND MATERIALS Two to four contouring methods for the middle ear, inner ear, temporal lobe, parotid gland and spinal cord were identifi...

متن کامل

The feasibility of evaluating radiation dose to the heart by integrating kilovoltage-cone beam computed tomography in stereotactic body radiotherapy of early non-small-cell lung cancer patients

BACKGROUND To investigate the feasibility of contouring the planning risk organ volume (PRV) for the heart, and to determine the probability of evaluating radiation dose to the heart using kilovoltage-cone beam computed tomography (kV-CBCT) in early-stage non-small-cell lung cancer (NSCLC) patients, who received stereotactic body radiotherapy (SBRT). MATERIALS AND METHODS Seventeen NSCLC pati...

متن کامل

Axillary irradiation in breast cancer; does meticulous contouring make a difference?

Background: Due to the current trends towards replacing axillary dissection with radiotherapy, the need for more precise definition for different nodal stations becomes a must to ensure safe and adequate dose coverage. So, our study aimed to evaluate the coverage of axillary nodal volumes based on Project on Cancer of the Breast (PROCAB) guidelines, for cases previously treated with our standar...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical oncology

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2005