Addition of Blood Pressure and Weight Transmissions to Standard Remote Monitoring of Implantable Defibrillators and its Association with Mortality and Rehospitalization.

نویسندگان

  • M Obadah Al-Chekakie
  • Haikun Bao
  • Paul W Jones
  • Kenneth M Stein
  • Lucas Marzec
  • Paul D Varosy
  • Frederick A Masoudi
  • Jeptha P Curtis
  • Joseph G Akar
چکیده

BACKGROUND Among patients with implantable defibrillators (ICD), use of remote patient monitoring (RPM) is associated with lower risk of death and rehospitalization. Standard ICD RPM can be supplemented with weight and blood pressure data. It is not known whether standard RPM plus routine weight and blood pressure transmission (RPM+) is associated with better outcomes. METHODS AND RESULTS RPM+ patients (n=4106) were compared with patients who only transmitted standard ICD RPM data (n=14 183). Logistic regression models identified patient, physician, and hospital characteristics associated with RPM+ utilization. Mortality and rehospitalization were examined using landmark analyses at 180 days after ICD implant in Medicare fee-for-service patients. In these analyses, we examined the independent association between RPM+ utilization and times to events up to 3 years after device implantation with Cox regression models. We further examined whether the association between RPM+ and outcomes varied by frequency or type of transmissions. Determinants of RPM+ utilization included impaired ejection fraction, cardiac resynchronization therapy, and institutional practice. The risk of mortality of RPM+ patients was similar to standard ICD RPM patients (hazard ratio, 1.06; 95% confidence interval, 0.94-1.19; P=0.34). RPM+ patients also had similar risks of all-cause hospitalization (subdistribution hazard ratio, 1.03; 95% confidence interval, 0.94-1.14; P=0.52), cardiovascular hospitalization (subdistribution hazard ratio, 0.92; 95% confidence interval, 0.83-1.02; P=0.15), or heart failure hospitalizations (subdistribution hazard ratio, 0.90; 95% confidence interval, 0.78-1.05; P=0.18). RPM+ transmission frequency was not associated with outcomes. CONCLUSIONS In patients using standard ICD RPM, the added transmission of weight and blood pressure data was not associated with improved outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.

INTRODUCTION Remote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network. METHODS Patients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy ...

متن کامل

Use of Remote Monitoring Is Associated With Lower Risk of Adverse Outcomes Among Patients With Implanted Cardiac Defibrillators.

BACKGROUND We examined the association between the use of remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICD) and all-cause mortality and rehospitalization among patients undergoing initial ICD implant. METHODS AND RESULTS A limited data set was constructed from Boston Scientific ALTITUDE Registry and National Cardiovascular Data Registry ICD Registry between Janu...

متن کامل

Determination of prevalence of being overweight and its association with hypertension in patients referred to the healthcare center in Jandaq in 2014.

Background and aims: Obesity and overweight is a major public health problem and, alongside hypertension, is one of the risk factors of cardiovascular diseases incidence. The aim of this study was to determine the prevalence of overweight and its association with hypertension in the patients referred the healthcare center in Jandaq. Methods: This cross-se...

متن کامل

Prevalence of hypertension and its association with certain demographic characteristics of blood donors in Ilam, Iran

Introduction: Hypertension is described as one of the risk factors for cardiovascular disease. The prevalence of hypertension is growing among developing countries. In this study, the prevalence of hypertension was studied in individuals who referred to blood transfusion center of Ilam city. Materials and methods: The present descriptive analytical study was performed based on available data. ...

متن کامل

Neural Monitoring With CMOS Image Sensors

Implantable image sensors have several biomedical applications due to their miniature size, light weight, and low power consumption achieved through sub-micron standard CMOS (Complementary Metal Oxide Semiconductor) technologies. The main applications are in specific cell labeling, neural activity detection, and biomedical imaging. In this paper the recent research studies on implantable CMOS i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular quality and outcomes

دوره 10 5  شماره 

صفحات  -

تاریخ انتشار 2017