Quality assurance using a photodiode array
نویسندگان
چکیده
Improved treatment techniques in radiation therapy provide incentive to reduce treatment margins, thereby increasing the necessity for more accurate geometrical setup of the linear accelerator and accompanying components. In the present paper, we describe the development of a novel device that enables precise and automated measurement of geometric parameters for the purpose of improving initial setup accuracy, and for standardizing repeated quality control activities. The device consists of a silicon photodiode array, an evaluation board, a data acquisition card, and a laptop. Measurements that demonstrate the utility of the device are also presented. Using the device, we show that the radiation light field congruence for both 6 and 15 MV beams is within 1.3 mm. The maximum measured disagreement between radiation field edges and light field edges was 1.290 ± 0.002 mm, while the smallest disagreement between the light field and radiation field edge was 0.016 ± 0.003 mm. Because measurements are automated, ambiguities resulting from interobserver variability are removed, greatly improving the reproducibility of measurements across observers. We expect the device to find use in consistency measurements on linear accelerators used for stereotactic radiosurgery, during the commissioning of new linear accelerators, or as an alternative to film or other commercially available devices for performing monthly or annual quality control checks.
منابع مشابه
2D linear array device as a quality assurance tool in brachytherapy applications
Background: External beam radiotherapy and brachytherapy plays a vital role in the management of cancer cervix. High dose rate brachytherapy is being presently used worldwide for the brachytherapy applications. At present, 2-Dimensional linear array detectors are the most common QA tool used for pretreatment patient specific quality assurance in external beam radiotherapy alon...
متن کاملA simple and rapid reversed-phase liquid chromatography (LC) method with photodiode array (PDA) and electrospray ionization
method with photodiode array (PDA) and electrospray ionization (ESI)–mass spectrometry (MS) as detectors was developed and validated to separate, identify, and quantitate the related substances of Doxazosin mesylate (DXZN) for monitoring the reactions involved during process development. The highperformance liquid chromatography profiles of related-substances of DXZN are used as fingerprints to...
متن کاملDesign and Manipulation 3D Imaging System by using Photodiode Grid
Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...
متن کاملRadiation Effects on Digital Radiography
In the moment of any given imaging task and thus over the lifetime of a detector, the deposition of certain amount of radiation dose in an electronic pixel element is inevitable. This radiation effect can give rise to a change of the pixel-element characteristics such as the leakage current of a photodiode and the threshold voltage of thin-film transistors (TFTs) [1], and which may consequently...
متن کاملA depth-dose measuring device using a multichannel scintillating fiber array for electron beam therapy.
The development of a new depth-dose measuring device for electron beam therapy is described. The device employs plastic scintillating fiber detectors inserted in a polymethylmethacrylate (PMMA) phantom in line along an incident electron beam. Output photons from a fiber, the number of which is proportional to the absorbed dose at each depth of the phantom, were converted to an electric signal w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -