Effect of Double Screw on Abutment Screw Loosening in Single-Implant Prostheses.

نویسندگان

  • Young-Gun Shin
  • So-Yun Kim
  • Ho-Kyu Lee
  • Chang-Mo Jeong
  • So-Hyoun Lee
  • Jung-Bo Huh
چکیده

PURPOSE This study was conducted to assess the effect of using a double screw on the prevention of abutment screw loosening. MATERIALS AND METHODS Internal connected abutment with a single screw (IS), internal connected abutment with a double screw (ID), external connected abutment with a single screw (ES), and external connected abutment with a double screw (ED) groups were prepared (n = 10 in each group). After 50,000 loading cycles, postload removal torque loss (RTL) percentage was measured. RESULTS Postload RTL of ID and ED were smaller than those of IS and ES (P = .000 and P = .039, respectively). CONCLUSION This study showed that a double screw was more effective in prevention of screw loosening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin mod...

متن کامل

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

Evaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020

Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school  in 2020. Methods: In this descriptive cross-sectional study, the pat...

متن کامل

Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data.

Screw loosening is considered to be a common problem with both screw-retained and cemented implant restorations. A wider abutment platform, as well as using a torque driver to tighten specifically designed screws may help prevent this loosening. However, there has been no clinical study evaluating either of these. To longitudinally compare the frequency of screw loosening in standard diameter, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of prosthodontics

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2016