Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
نویسنده
چکیده
In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing interferometer. The first step in the research on such sensor is the assessment of its performance under favorable conditions, i.e., using blood samples from healthy volunteers tested in vitro. Such an experiment was conducted using a sensor comprising a superluminescent diode source, an optical spectrum analyzer working as the detection setup and a sensing Fabry-Perot interferometer providing high interference contrast. The response of this sensor was recorded for several samples and compared with the reference laboratory method. The coefficient of determination (R²) for a linear relationship between the results given by both methods was 0.978 and the difference between these results was less than 1%. The presented results suggest that further research into the performance of the sensor is merited.
منابع مشابه
Design, simulation and Fabrication of Circularly Polarized Fabry-Perot Antenna for Ku Band
This paper deals with the design and simulation of a RHCP Fabry-Perot antenna for 14.5 GHz. Based on transmission line model, partially Reflecting Surface (PRS) was designed so thatgain enhancement and circular polarization simultaneously obtained. PRS consist of a square loop and meander-line at the top and bottom respectively. In order to achieve the resonance condition in orthogonal componen...
متن کاملDesign of Optical Fiber Fabry-Perot Sensors Based on Intensity and Phase with Parallel Processing
For fiber Fabry-Perot sensor vulnerable to external parameters such as electromagnetic, noise and displacement impact, reducing the problem resilience, research and design new fiber Fabry-Perot sensor with parallel processing capabilities based on the intensity and phase of perception. First, according to various types of external parameters and the degree of interference, established the inten...
متن کاملChitosan Layer Fabry - Perot Interferometer - Based Optical Fiber Sensor for Cadmium Ion Detection
Optical sensors based on Fabry-Perot interferometer to detect cadmium ions is proposed. The sensor was fabricated by coating the tip of the optical fiber by chitosan. The two chitosan surfaces serve as mirrors which form a Fabry-Perot interferometer. The characterization results indicate that the sensor has a linear response with sensitivity of 0.0884 dBm/ppm with a correlation factor of 0.9665...
متن کاملDesign Studies of Integrated Fabry-Perot Sensor Based on Bragg Grating Mirrors
In this work the results of the theoretical studies of photonic integrated circuit refractive index sensor based on quasi1D Bragg grating configurations which act as a Fabry-Perot interferometers are presented. The variation of the medium refractive index is detected by monitoring the shift of the spectral maxima of the Fabry-Perot cavity. The sensor has been designed using the analytical expre...
متن کاملFiber optic extrinsic Fabry-Perot interferometric sensor for high blast pressure measurement
Optical fiber based Extrinsic Fabry-Perot Interferometric (EFPI) sensor significantly emerged as an advanced optical sensor for the health monitoring of civil, mechanical and aeronautical structures. This sensor responds its well capability also towards the measurement of acoustic/shock wave pressure. This paper presents an approach for high blast (acoustic/shock wave) pressure measurement usin...
متن کامل