Effect of hinge gap width on the microflow structures in 27-mm bileaflet mechanical heart valves.

نویسندگان

  • Hwa-Liang Leo
  • Hélène A Simon
  • Lakshmi P Dasi
  • Ajit P Yoganathan
چکیده

BACKGROUND AND AIM OF THE STUDY Most bileaflet mechanical heart valves (BMHVs) incorporate some retrograde flow through their hinge mechanism to prevent flow stasis and inhibit microthrombus formation. This reverse flow is characterized by high velocities and shear stresses, thereby promoting platelet activation and hemolysis inside the hinge region. In the present study, the thromboembolic potential of three 27-mm BMHVs with varying hinge gap widths was assessed via in-vitro characterization of the hinge microflow structures. METHODS Three 27-mm BMHV prototypes with different hinge gap widths (50, 100, and 200 microm) were provided by St. Jude Medical Inc. The valves were mounted in the mitral position of a left heart flow simulator, and two-dimensional laser Doppler velocimetry was used to measure the hinge velocity fields. RESULTS All three valve prototypes revealed Reynolds shear stress (RSS) levels above 2000 dynes/cm2, which exceeded the threshold for platelet activation and hemolysis. The hinge flow fields were characterized by leakage jets during systole, and a strong vortical flow during diastole. The leakage jet size and corresponding RSS levels were found to increase with the hinge gap width. All three gap widths had RSS >4000 dynes/cm2 (range: 5640 to 13,315 dynes/cm2). The hinge with the smallest gap width registered the highest jet velocity magnitude (2.08 m/s) during systole. CONCLUSION The study results showed that the hinge gap width influences washout and RSS levels inside the hinge recess. The 100-microm hinge gap width provided optimum fluid dynamic performance. In contrast, the two valves with large and small hinge gap widths may have higher thromboembolic potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry.

The regurgitant flow fields of clinically used mechanical heart valves have been traditionally studied in vitro using flow visualization, ultrasound techniques, and laser Doppler velocimetry under steady and pulsatile flow. Detailed investigation of the forward and regurgitant flow fields of these valves can elucidate a valve's propensity for blood element damage, thrombus formation, or cavitat...

متن کامل

Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.

The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional mode...

متن کامل

An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.

BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flo...

متن کامل

Structural analysis of a bileaflet mechanical heart valve prosthesis with curved leaflet

Structural analysis, especially the thickness effect on the structural strength, of a bileaflet mechanical heart valve prosthesis with curved leaflets is presented in this paper. Taking the wide variations of the blood flow pressure on the leaflet surface, the structural stresses inside the leaflet and deflections of the leaflet are investigated by adopting both linear and nonlinear structural ...

متن کامل

Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Chinese Multicenter Clinical Study

BACKGROUND The aim of this study was to investigate the incidence and immediate and mid-term effects of heart valve prosthesis-patient mismatch (PPM) after mitral valve replacement using the GK bileaflet mechanical valve. MATERIAL AND METHODS A total of 493 cases of mechanical mitral valve replacement were performed in the departments of cardiac surgery in 7 hospitals from January 2000 to Jan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of heart valve disease

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2006