PET-measured responses of MBF to cold pressor testing correlate with indices of coronary vasomotion on quantitative coronary angiography.
نویسندگان
چکیده
UNLABELLED The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P <or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P < 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P <or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.
منابع مشابه
Chronic inflammation and impaired coronary vasoreactivity in patients with coronary risk factors.
BACKGROUND The goal of this study was to examine a possible association between systemic microinflammation, as reflected by C-reactive protein (CRP) serum levels, and coronary vasomotion in patients with coronary risk factors but with angiographically normal coronary arteries. METHODS AND RESULTS Coronary vasomotor function was studied in response to cold pressor testing (CPT) in 71 patients ...
متن کاملMeasurement of myocardial blood flow response to the cold pressor test with myocardial perfusion CMR
Background The CPT induces endothelial-dependent vasodilation with increased myocardial blood flow (MBF) in normal coronary arteries. It has been used to demonstrate abnormal coronary vasomotion by invasive (angiography) and non-invasive techniques (SPECT and PET). Cardiovascular Magnetic Resonance (CMR) allows the assessment of MBF in separate myocardial layers due to its high spatial resoluti...
متن کاملL-Arginine normalizes coronary vasomotion in long-term smokers.
BACKGROUND Noninvasive measurements of myocardial blood flow (MBF) with PET revealed an abnormal coronary vasomotor response to cold pressor test in healthy long-term smokers. If coronary endothelial dysfunction accounted for this abnormality, we hypothesized that it could be reversed by L-arginine as the substrate for NO synthase. METHODS AND RESULTS MBF was quantified with 13N-labeled ammon...
متن کاملSmoking cessation normalizes coronary endothelial vasomotor response assessed with 15O-water and PET in healthy young smokers.
UNLABELLED Cigarette smoking is one of the risk factors of cardiovascular diseases and is related to abnormal peripheral and coronary vascular vasomotion. Coronary vascular endothelial dysfunction is caused by chronic smoking in smokers without epicardial coronary artery stenosis. The coronary endothelial vasomotion abnormality is restored by interventions such as l-arginine or vitamin C infusi...
متن کاملEffects of long-term smoking on myocardial blood flow, coronary vasomotion, and vasodilator capacity.
BACKGROUND The effect of long-term smoking on coronary vasomotion and vasodilator capacity in healthy smokers is unknown. METHODS AND RESULTS Myocardial blood flow (MBF) was quantified with [13N]ammonia and positron emission tomography (PET) at rest, during cold pressor testing (endothelium-dependent vasomotion), and during dipyridamole-induced hyperemia in 16 long-term smokers and 17 nonsmok...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2004