Studies on the separation of 99mTc from large excess of molybdenum.

نویسندگان

  • Wioletta Wojdowska
  • Dariusz Pawlak
  • Józef L Parus
  • Renata Mikołajczak
چکیده

BACKGROUND Due to aging and unexpected prolonged shutdown of nuclear reactors producing ⁹⁹Mo for ⁹⁹Mo/ 99mTc generators it was necessary to explore the alternative methods of technetium-99m production. The first choice were the accelerators. Three years ago IAEA (International Atomic Energy Agency) initiated the Coordinated Research Project "Accelerator-based Alternatives to Non-HEU production of Mo-99 /Tc-99m" aimed at direct production of 99mTc in proton accelerators using the ¹⁰⁰Mo(p,2n)99mTc reaction. POLATOM is participating in this enterprise together with the Heavy Ion Laboratory of Warsaw University and the Institute of Nuclear Chemistry and Technology. MATERIAL AND METHODS ⁹⁹Mo/99mTc solutions and pure 99mTc used for generators production or milked from ready to use generators were used in experiments. Commercial chromatographic and laboratory-prepared columns were used for separation. The peristaltic pumps were used for solutions delivery onto the columns. Radioactivity of eluted ⁹⁹Mo and 99mTc was measured using high resolution gamma spectrometry or ionisation chamber in case of high radioactivity. For separation, three different chromatographic methods were used, one based on ion exchange and two on extraction. RESULTS Synthetic mixtures simulating the real solutions were used. 99mTc is quantitatively bound in the Dowex-1 × 8 column whereas molybdenum is only slightly retained and totally rinsed with 2M NaOH. 99mTc is eluted with TBAB. The elution yield has been reproducible and amounted to 78%. The AnaLig Tc-02 resin column was used for 99mTc retention. Residual Mo was removed by rinsing with 2M NaOH and 99mTc eluted using small volume of water. The recovery was equal to about 85%. Using C-18 column coated with PEG over 80% of 99mTc was recovered in about 50 mL of water. The reduction of volume was necessary. CONCLUSIONS The recovery of 99mTc was the highest using AnaLig Tc-02 resin. Time of 99mTc separation is the shortest for AnaLig Tc-02 resin and it is not higher than 100 minutes and it can further be shortened.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New precipitation method for isolation of 99mTc from irradiated 100Mo target

Technetium-99m is the most widely used radionuclide in nuclear medicine. This work describes the method to separate 99mTc from irradiated 100Mo target. For this purpose we utilized formation of ammonium molybdenum phosphate (AMP) and have optimized the four parameters of the process. The proposed process is promising and allows fast separation of macroamounts of molybdenum without co-precipitat...

متن کامل

Optimization of the rate of production 99Mo-99mTC through fission in the TRR

Technetium is one of the most important radioisotopes recognized in medicine which is obtained through ‎the decay of molybdenum 99.The half-life of this radioisotope is 6 hours and it is capable of 140 kev gamma ray emission. Due to its short half-life, this radioisotope must be produced at the site of consumption, so that the shortest possible time interval between production and consumption c...

متن کامل

Molybdenum-Schiff Base Complex Immobilized on Magnetite Nanoparticles as a Reusable Epoxidation Catalyst

The surface of magnetite nanoparticles as nano-sized solid support was modified with a molybdenum-Schiff base complex to prepare an easily separable heterogeneous catalyst for the epoxidation of olefins. Characterization techniques such as Fourier transform infrared and inductively coupled plasma optical emission spectroscopies, X-ray diffraction, vibrating sample magnetometry, scanning, an...

متن کامل

Investigation on selective rhenium leaching from molybdenite roasting flue dusts

The possibility of selective leaching process was investigated during molybdenite flue dust leaching to recover its rhenium content. The results show that addition of alcohols to water makes the medium less favorable for molybdenum transfer into aqueous phase. On the other hand, addition of small amounts of alcohols (5-15%) makes a noticeable separation of rhenium over molybdenum, but by increa...

متن کامل

Extraction of Molybdenum (VI) and Vanadium (V) from Nitrate Solutions Using Coupling of Acid and Solvating Extractants (RESEARCH NOTE)

In this study, solvent extraction method has been utilized for separation of molybdenum and vanadium from nitrate solution by utilizing coupling of acid and solvating extractants (D2EHPA and TBP extractants). The outcomes demonstrated that synergistic solvent extraction improves stability of formatted complexes for transfer to the organic phase. The main parameters such as pH value, concentrati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2015