Pressure-assisted capillary electrophoresis electrospray ionization mass spectrometry for analysis of multivalent anions.

نویسندگان

  • Tomoyoshi Soga
  • Yuki Ueno
  • Hisako Naraoka
  • Keiko Matsuda
  • Masaru Tomita
  • Takaaki Nishioka
چکیده

We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a noncharged polymer, poly(dimethylsiloxane), coated to the inner surface of the capillary to prevent anionic species from adsorbing onto the capillary wall. It was also necessary to drive a constant liquid flow toward the MS by applying air pressure to the inlet capillary during electrophoresis to maintain a conductive liquid junction between the capillary and the electrospray needle. Although theoretical plates were inferior to those obtained by CE/ESI-MS using a cationic polymer-coated capillary, the PACE/ESI-MS method improved reproducibility and sensitivity of these anions. Eighteen anions were separated by PACE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. The relative standard deviations (n = 6) of the method were better than 0.6% for migration times and between 1.4% and 6.2% for peak areas. The detection limits for these species were between 0.4 and 3.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL), that is, mass detection limits calculated in the range from 12 to 110 fmol at a signal-to-noise ratio of 3. The utility of the method was demonstrated by analysis of citrate isomers, nucleotides, dinucleotides, and CoA compounds extracted from Bacillus subtilis cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of liquid chromatography-atmospheric pressure ionization-mass spectrometry in water analysis ^ Part I: Achievements

Liquid chromatography-mass spectrometry using atmospheric pressure ionization is dramatically changing the analytical methods, potential and tasks of water analysis. The present status in applying this technique to organic as well as inorganic water constituents and its use in the context of wastewater treatment and drinking water preparation is reviewed. Separation techniques such as reversed-...

متن کامل

Analysis of hop acids and their oxidized derivatives and iso-alpha-acids in beer by capillary electrophoresis-electrospray ionization mass spectrometry.

This study investigates the applicability of on-line coupling of capillary electrophoresis with electrospray ionization tandem mass spectrometry (CZE-ESI-MS) for the separation and characterization of alpha- and beta-acids and oxidized hop acids from crude extracts of different hop varieties. CZE-ESI-MS with negative-ion electrospray ionization proved to be a suitable technique for the determin...

متن کامل

Rapid Biomolecule Analysis Using Two-dimensional Electrophoresis-electrospray Ionization Microchip

We demonstrate a two-dimensional (2D) separation microchip allowing capillary isoelectric focusing-capillary zone electrophoresis (cIEF-CZE) to be coupled to electrospray ionization mass spectrometry (ESI/MS). In the first dimension, separation is according to pI values (cIEF), while CZE occurs in the second dimension during mobilization towards the monolithically integrated ESI emitter. The se...

متن کامل

Capillary electrophoresis-electrospray ionization mass spectrometry of amino acids, peptides, and proteins.

Separation in capillary electrophoresis (CE) is based on the movement of charged compounds inside a background electrolyte under an applied potential. Because the mechanism of separation of CE differs from that of conventional high-performance liquid chromatography (HPLC), where separation is based on the analyte's hydrophobic properties, CE is often used as a complementary technique to HPLC. I...

متن کامل

Analysis of phospholipase A2 glycosylation patterns from venom of individual bees by capillary electrophoresis/electrospray ionization mass spectrometry using an ion trap mass spectrometer.

A method based on tryptic digestion, ultrafiltration and capillary electrophoresis/mass spectrometry (CE/MS) has been developed for the analysis of the glycosylation pattern in the phospholipase A2 (PLA) of individual honeybees. Without reducing the disulfide bonds, PLA was digested with trypsin and filtered with a 3 kDa molecular weight (MW) cut-off membrane. With this procedure, the glycopept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 24  شماره 

صفحات  -

تاریخ انتشار 2002