Influence of steep Trendelenburg position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy.

نویسندگان

  • A F Kalmar
  • L Foubert
  • J F A Hendrickx
  • A Mottrie
  • A Absalom
  • E P Mortier
  • M M R F Struys
چکیده

BACKGROUND The steep (40 degrees ) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to investigate the combined effect of this position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during these procedures. METHODS Physiological data were recorded during the whole surgical procedure in 31 consecutive patients who underwent robotic endoscopic radical prostatectomy under general anaesthesia. Heart rate, mean arterial pressure, central venous pressure, Sp(o(2)), Pe'(co(2)), P(Plat), tidal volume, compliance, and minute ventilation were monitored and recorded. Arterial samples were obtained to determine the arterial-to-end-tidal CO(2) tension gradient. Continuous regional cerebral tissue oxygen saturation (Sct(o(2))) was determined by near-infrared spectroscopy. RESULTS Although patients were in the Trendelenburg position, all variables investigated remained within a clinically acceptable range. Cerebral perfusion pressure (CPP) decreased from 77 mm Hg at baseline to 71 mm Hg (P=0.07), and Sct(o(2)) increased from 70% to 73% (P<0.001). Pe'(co(2)) increased from 4.12 to 4.79 kPa (P<0.001) and the arterial-to-Pe'(co(2)) tension difference increased from 1.06 kPa in the normal position to a maximum of 1.41 kPa (P<0.001) after 2 h in the Trendelenburg position. CONCLUSIONS The combination of the prolonged steep Trendelenburg position and CO(2) pneumoperitoneum was well tolerated. Haemodynamic and pulmonary variables remained within safe limits. Regional cerebral oxygenation was well preserved and CPP remained within the limits between which cerebral blood flow is usually considered to be maintained by cerebral autoregulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral haemodynamic physiology during steep Trendelenburg position and CO(2) pneumoperitoneum.

BACKGROUND The steep (40°) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to elucidate the influence of this patient positioning on cerebral blood flow and zero flow pressure (ZFP), and to assess the validity of different methods of evaluating ZFP. METHODS In 21 consecutive patients who underwent robotic endoscopic radical pr...

متن کامل

Arterial to end-tidal carbon dioxide pressure gradient increases with age in the steep Trendelenburg position with pneumoperitoneum

BACKGROUND Several factors affect the end-tidal carbon dioxide pressure (P(ET)CO(2)) and increase the arterial to end-tidal carbon dioxide pressure gradient (P(a-ET)CO(2)) during general anesthesia. We evaluated the relationship between age and P(a-ET)CO(2) during pneumoperitoneum in the steep Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy (RALP). METH...

متن کامل

Effects of steep Trendelenburg position and pneumoperitoneum on middleear pressure in patients undergoing robotic radical prostatectomy.

BACKGROUND/AIM The aim of this study was to quantify the changes in middle ear pressure (MEP) during robot-assisted radical prostatectomy (RARP). MATERIALS AND METHODS Thirty patients undergoing RARP were included in this study. MEP was obtained at the following time points: awake (T1), postintubation (T2), pneumoperitoneum + 1 h of Trendelenburg position (T3), pneumoperitoneum + 2 h of Trend...

متن کامل

Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position

BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...

متن کامل

[Robotic prostatectomy: The anesthetist's view for robotic urological surgeries, a prospective study].

BACKGROUND AND OBJECTIVES Although many features of robotic prostatectomy are similar to those of conventional laparoscopic urological procedures (such as laparoscopic prostatectomy), the procedure is associated with some drawbacks, which include limited intravenous access, relatively long operating time, deep Trendelenburg position, and high intra-abdominal pressure. The primary aim was to des...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 104 4  شماره 

صفحات  -