DVCC based Readout Circuitry for Water Quality Monitoring System
نویسندگان
چکیده
A new configuration realizing water quality monitoring device using ISFET involving CMOS differential voltage current conveyor (DVCC) based low pass filter free from trans-conductance variation using Low-voltage PMOS bulkdriven cascade current mirror (P MOS BDCCM) current mirrors is proposed. The circuit uses four DVCCs as active elements and together with two capacitors and five resistors as passive elements, only one current mirror. The use of this active component makes the implementation simple and attractive. The functionality of the circuit is tested using Tanner simulator version 15 for a 70nm CMOS process model also the transfer function realization is done on MATLAB R2011a version, the Very high speed integrated circuit Hardware description language(VHDL) code for the same scheme is simulated on Xilinx ISE 10.1 and various simulation results are obtained. Simulation results are included to demonstrate the results.
منابع مشابه
Assessment of Guinea Savanna River system to evaluate water quality and water monitoring networks
The analysis of changes in water quality in a monitoring network system is important because the sources of pollution vary in time and space. This study utilized analysis of the water quality index calculation, hierarchical cluster analysis, and mapping. This was achieved by assessing the water quality parameters of the samples collected from Galma River in Zaria, Northwestern Nigeria in wet an...
متن کاملA miniaturized low-power wireless remote environmental monitoring system based on electrochemical analysis
In this paper, we report a miniaturized low-power wireless remote environmental monitoring system. This system has been developed for on-site monitoring of water pollution by heavy-metal ions. The system is composed of three parts: an electrochemical sensor module using microfabricated electrodes for detecting heavy-metal contamination in sample water; a custom potentiostat module including rea...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملClosed-Loop Compensation of the Quadrature Error in MEMS Vibratory Gyroscopes
In this paper, a simple but effective method for compensation of the quadrature error in MEMS vibratory gyroscope is provided. The proposed method does not require any change in the sensor structure, or additional circuit in the feedback path. The mathematical relations of the proposed feedback readout system were analyzed and the proposed solution assures good rejection capabilities. Based on ...
متن کاملCell-Based Sensor System Using L6 Cells for Broad Band Continuous Pollutant Monitoring in Aquatic Environments
Pollution of drinking water sources represents a continuously emerging problem in global environmental protection. Novel techniques for real-time monitoring of water quality, capable of the detection of unanticipated toxic and bioactive substances, are urgently needed. In this study, the applicability of a cell-based sensor system using selected eukaryotic cell lines for the detection of aquati...
متن کامل