A systematic review and meta-analysis of the diagnostic accuracy of ultrasound-guided core needle biopsy for salivary gland lesions.

نویسندگان

  • Robert L Schmidt
  • Brian J Hall
  • Lester J Layfield
چکیده

Core needle biopsy (CNB) of salivary gland lesions is a relatively new technique that may offer benefits for diagnosis of the lesions. We conducted a systematic literature review to identify studies published between January 1, 1985, and March 15, 2011. Summary estimates of sensitivity and specificity were obtained by using a summary receiver-operating characteristic (SROC) curve. Study quality was assessed by using the QUADAS survey. We identified 5 studies (277 cases) for inclusion. The area under the SROC for CNB was 1.00 (95% confidence interval [CI], 0.99-1.00). Based on histologically verified cases, the sensitivity of CNB is 0.92 (95% CI, 0.77-0.98) and the specificity is 1.00 (95% CI, 0.76-1.00). We conclude that CNB has high accuracy and a low (1.2%) inadequacy rate. CNB is more accurate than fine-needle aspiration, at least in some settings, but the best selection of which test to use for an individual patient and setting remains to be defined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-guided core needle biopsy of salivary gland lesions: a systematic review and meta-analysis.

OBJECTIVES/HYPOTHESIS To obtain summary estimates of the sensitivity and specificity of core needle biopsy for assessment of salivary gland lesions and to investigate sources of variation in accuracy between study locations. STUDY DESIGN Data sources were PubMed, Embase, CAB Abstracts, CINAHL, BIOSIS, LILACS, PakMediNet, Trip Database, and the National Guideline Clearinghouse. Scopus was used...

متن کامل

Reply to letter to the editor

To the Editor: I wish to comment on several methodological issues in a recent systematic review and meta-analysis on the diagnostic accuracy of ultrasound-guided core-needle biopsy for head and neck lesions. This study suffers from several problems that are commonly seen in meta-analyses of diagnostic accuracy studies. First, meta-analysis requires specialized statistical methods to synthesize ...

متن کامل

Methodological issues in meta-analysis of diagnostic accuracy studies.

To the Editor: I wish to comment on several methodological issues in a recent systematic review and meta-analysis on the diagnostic accuracy of ultrasound-guided core-needle biopsy for head and neck lesions. This study suffers from several problems that are commonly seen in meta-analyses of diagnostic accuracy studies. First, meta-analysis requires specialized statistical methods to synthesize ...

متن کامل

Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

BACKGROUND Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. METHODS We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. ...

متن کامل

Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

BACKGROUND AND PURPOSE Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 136 4  شماره 

صفحات  -

تاریخ انتشار 2011