Analog Simulator Tests Qualify Distance Relay Designs to Today’s Stringent Protection Requirements
نویسندگان
چکیده
Deregulation, increased loads, and limited resources/rights-of-way available for the building of new transmission lines are routinely pushing modern power transmission networks to operating limits. New generations of microprocessor relays provide design opportunities that help stressed transmission networks meet protection requirements. To verify that increasingly complex microprocessor relays fulfill design specifications and utility protection requirements, China EPRI has designed an analog simulator test system to test many new designs of name-brand microprocessor relays. This paper draws upon many years of test experience to provide a summary of the common areas presenting the greatest challenges to distance relay designs. These challenges include evolving faults, faults with high fault resistance, power swing blocking, and reliable fault clearance during system power swings. The paper introduces ways that relay manufacturers have adapted and improved performance of their relays in these problematic areas. The paper compares the differences between analog and digital simulator systems and points out unique characteristics of each system. This paper focuses mainly on distance relay qualifications and applications for high-voltage transmission systems. I. MODERN REQUIREMENT FOR DISTANCE PROTECTION In the past several years, power transmission systems in China have expanded enormously. Increased power system complexity calls for corresponding protection device improvement. As the Chinese economy has expanded, transmission lines have needed to transmit more power to satisfy increased load. Following newly established policies of transporting power from western to eastern China and interconnecting regional power networks, transmission lines have become increasingly longer. To improve transmission line capacity, the Chinese have added series-capacitor compensation including Fixed Static Var Compensator (FSC) and Thyristor-Controlled Series Capacitor (TCSC) to the power system. Distance protection relays, although widely used for transmission line protection, must meet the following stringent requirements of power system development: • Relay operating time must be less than 20 ms for metallic faults along the entire length of the protected line, which means a sub-cycle tripping time for 50 Hz transmissions systems. • Transient overreach error of distance elements must be less than 5 percent. • Relays must correctly identify the faulted phase for single-line-to-ground (SLG) faults. • Distance relays must not misoperate during power swings. These power swings include those occurring during normal system operations when all three breaker poles are closed or those occurring during a single-phase open period following a successful trip of an SLG fault (phase-open or unsymmetrical power swings). • Distance relays normally have a power swing blocking (PSB) function to detect power swings and block distance elements. Any PSB must be removed to allow distance protection operations after the relay detects additional faults during a power swing. • Distance relays must operate correctly for seriescapacitor-compensated (SC) systems. • Relays must correctly identify the faulted phase when there is no overlap between external and internal faults in an evolving fault situation. Although designing a distance relay to meet all of these requirements is challenging, safe power system operation depends upon such a design. In China, a newly developed protection relay must undergo a comprehensive validation test to verify that it will meet all requirements before the relay can be installed on Chinese high-voltage transmission systems. During the test, a relay is subjected to several thousand faults or abnormal operating conditions. Several different system models are used to generate the different fault scenarios and operating conditions. These simulator tests often reveal design flaws and allow relay manufacturers to correct or improve firmware and algorithms before the relay is placed in service. The simulator test dramatically reduces the possibility of relay misoperations in the actual power system. II. ANALOG SIMULATOR TEST FOR DISTANCE PROTECTION In China, qualification testing of protection relays is done mainly through use of an analog simulation system. The dynamic simulation test is essential to determining the overall performance of a protection relay. The test center at the China Electric Power Research Institute (CEPRI) has tested various kinds of distance protection relays. Models that accurately represent the actual power systems and well-designed test
منابع مشابه
Distance protection closed-loop testing using RTDS
This paper presents a distance protection test procedure by applying the Real-Time Digital Simulator (RTDS) of a power system. RTDS is a tool to design, develop, and test power-system protection. The RTDS enables real-time computation of electromagnetic phenomena with a calculation time step of even 50μs. The hardware allows the import and export of many signals from the simulator to an ext...
متن کاملZone-3 Impadance Reach Setting of Distance Relays by Including In-feed Current Effects in an Adaptive Scheme
The undesired operation of zone 3 may be one of the most conspicuous protective relay features due to the incorrect zone 3 relay operations which have been conducive to the severity of blackouts. Therefore, determining the accurate zone 3 setting of the distance relay is deemed to be necessary. This paper focuses on the development of a new technique for calculating zone-3 setting of distance r...
متن کاملA new interval approach for setting the distance relay zones to achieve perfect selectivity and maximum sensitivity
In this paper, an interval approach is presented to achieve perfect selectivity and maximum sensitivity in distance relay zones, considering uncertainties. For this purpose, first, the uncertainties affecting the settings of the three zones of a distance relay are discussed. Then, by using the Monte-Carlo simulation, the uncertainties are modelled and the impedances seen by the distance relay a...
متن کاملA new interval approach for setting the distance relay zones to achieve perfect selectivity and maximum sensitivity
In this paper, an interval approach is presented to achieve perfect selectivity and maximum sensitivity in distance relay zones, considering uncertainties. For this purpose, first, the uncertainties affecting the settings of the three zones of a distance relay are discussed. Then, by using the Monte-Carlo simulation, the uncertainties are modelled and the impedances seen by the distance relay a...
متن کاملConsidering Pilot Protection in the Optimal Coordination of Distance and Directional Overcurrent Relays
The aim of the relay coordination is that protection systems detect and isolate the faulted part as fast and selective as possible. On the other hand, in order to reduce the fault clearing time, distance protection relays are usually equipped with pilot protection schemes. Such schemes can be considered in the distance and directional overcurrent relays (D&DOCRs) coordination to achieve faster ...